verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

GFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain

The AirTAC GFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$56.80 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain

The GFR300C15AJC1T is an AirTAC GFR-series filter regulator: water and particulate filtration plus downstream pressure regulation in a single body. This size 300 unit carries a 1/2 in NPT port, a 40 um standard filter element, and an automatic drain that expels collected condensate without manual attention. The standard regulator covers an adjustment range of 0.15-0.9 MPa (20-130 psi) with a maximum inlet pressure of 1.0 MPa (145 psi), and this configuration is fitted with an external round pressure gauge scaled in MPa. Operating temperature is -5 to 70 C (non-freezing), and the size 300 bowl is PC (polycarbonate).

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, and is available with manual or differential-pressure drains as well as automatic, a 5 um (code W) element option, square or round gauges scaled in MPa, psi or bar, G or NPT thread options, and bracket choices. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet figures for your application.

GFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain Technical Specifications

ModelGFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain
SeriesGFR300 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain

GFR300G-series filter regulator, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · See datasheet · 40 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-C1 (two-unit set)

Where the GFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain Is Used

precision_manufacturing

CNC machining centre air supply

Point-of-use conditioning ahead of tool-clamp and chuck actuation circuits on a machining centre: the 40 um element strips water and swarf-carried particulate from the shop-air drop, while the regulator holds a stable setting to the clamp valves and the automatic drain keeps the bowl clear between shifts.

conveyor_belt

Packaging line conveyor actuators

Mounted at the drop feeding cylinder-driven pushers, gates and stop stations on a packaging conveyor, this filter regulator delivers clean air at a fixed pressure so cylinder strokes stay repeatable, with the round MPa gauge giving operators a visible setpoint at the machine.

factory

Plant air ring main take-offs

Installed on branch take-offs from a factory compressed-air ring main, the unit conditions and regulates air for downstream valves and air tools on that branch; the 1/2 in NPT port suits main-line branch piping and the automatic drain handles condensate in runs that are rarely visited.

Is the GFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain the Right Unit?

Start with the port step: this unit is size 300 with a 1/2 in port, one of five sizes (200/300/400/600) stepping up in port and flow capacity - match the step to your line's air demand. Choose the drain to suit access: automatic (this unit) suits unmanned or hard-to-reach installations, manual suits attended stations, and differential-pressure drain is the default. The 40 um element is standard; specify the 5 um W-code element where finer particulate removal is needed. Gauge scale (MPa, psi or bar) and thread (PT standard, with G and NPT as order options) are decodable choices, and brackets are optional on GFR.

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated number, so we do not quote a flow figure here. Send us your application details and we will confirm the sizing against the datasheet curves before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain FAQ

AirTAC publishes flow for the GFR family as curves, not as a single rated figure, so we do not quote a l/min, m3/h or SCFM number here. Tell us your inlet pressure, set pressure and expected air demand, and we will confirm the sizing against the datasheet curves before you order.

The A in the code specifies an automatic drain, which expels collected condensate from the bowl without operator attention - the right choice for unmanned cells or hard-to-reach mounting points. GFR300 units are also orderable with a manual drain or the differential-pressure drain default, and the drain choice also sets the regulator adjustment range: automatic and differential-pressure drains give 0.15-0.9 MPa (20-130 psi), while a manual drain widens the bottom of the range to 0.05-0.9 MPa (7-130 psi).

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR300C15AJC1T AirTAC Filter Regulator NPT1/2, Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR300C15AJC1T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.