The AirTAC GFR300C15C2WG AirTAC Filter Regulator G1/2, 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR300C15C2WG is an AirTAC GFR300 filter regulator: a 300-size unit that removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is tapped G1/2 (1/2 in BSPP), carries the fine 5 um filter element (code W), drains condensate by differential pressure, and is fitted with an external round gauge reading in psi. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) setting range, a reverse/check valve is not fitted, and a mounting bracket is included.
It is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drain, 40 um or 5 um filtration, square or round gauges with MPa, psi or bar scales, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application.
| Model | GFR300C15C2WG AirTAC Filter Regulator G1/2, 5 um |
|---|---|
| Series | GFR300 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · See datasheet · 40 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-C1 (two-unit set) |
Point-of-use water removal and pressure regulation at 1/2 in air drops feeding impact wrenches, pneumatic clamps and lift-assist cylinders on a car body assembly line.
Clean, regulated air for carton-forming and case-sealing cylinders on a packaging conveyor, with the 5 um element protecting the directional valves and the psi gauge giving operators a direct setting check.
Stable regulated supply to pneumatic actuators on sample-handling and analytical equipment, where the 5 um grade and psi-scale round gauge suit instrument-adjacent panels.
Size first: G-series air treatment steps through sizes 200, 300, 400 and 600, each with larger ports and greater flow capacity, so choose the size whose flow curve covers your demand at working pressure rather than upsizing blindly. Drain type is a real decision: differential-pressure drain (this model) needs no routine attention, automatic drain empties the bowl on its own, and manual drain suits intermittent duty. Filter grade matters too - 40 um is the standard element, while 5 um (code W, fitted here) protects finer valves and instruments. Gauges come as the embedded square type or an external round gauge, scaled in MPa, psi or bar, and threads are PT as standard with G and NPT available to order. Brackets are optional on the individual families. Because AirTAC publishes flow only as curves, not a single rated figure, send us your application details and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for this family as curves, not as a single rated figure, so we do not quote a number here. Tell us your working pressure and demand and we will confirm the flow from the datasheet and check the sizing against your application before you order.
The W code in GFR300C15C2WG selects the optional 5 um filter element, which removes finer particulate than the 40 um standard and is chosen to protect sensitive valves, cylinders and instruments. If your circuit does not need fine filtration, the 40 um standard grade is the default choice.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.