verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain

The AirTAC GFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$123.27 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain

The AirTAC GFR600C20AJF2G is a size-600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration carries a G3/4 (BSPP) port, a 40 um standard filter element, an automatic drain that expels collected condensate without manual attention, an embedded square gauge reading in psi, a standard regulation range of 0.15-0.9 MPa (20-130 psi), and no mounting bracket. The size-600 bowl is aluminium alloy. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 to 1 inch, and can be ordered with manual or differential-pressure drains, a 5 um element (code W), alternative gauge scales (MPa, psi or bar), G or NPT threads, and an optional reverse/check valve. Flow is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

GFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain Technical Specifications

ModelGFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain Is Used

factory

Packaging machine air preparation

Fit this G3/4 filter regulator at the air inlet of a packaging line so wrappers, sealers and pick-and-place cylinders receive cleaned air at the pressure the machine was set up for, with condensate drained automatically between shifts.

conveyor_belt

Conveyor stop-and-gate actuation

Use the unit on the supply to conveyor gates, diverters and stopper cylinders, holding a steady set pressure so indexing and product stops stay repeatable while the 40 um element keeps debris out of the valve seats.

handyman

Maintenance shop drop-line regulation

Install it on a workshop drop line feeding impact wrenches, air ratchets and blowguns, giving technicians a psi gauge to set tool pressure at the point of use and an automatic drain that copes with a shared, humid supply.

Is the GFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain the Right Unit?

Step up or down through the GFR sizes (200/300/400/600) and their port sizes (1/8 to 1 inch) according to the flow your line needs - larger sizes carry larger ports and more flow, and we will confirm the flow curve against your demand before you order. Choose the drain to suit the installation: this unit has an automatic drain, best where the bowl is hard to reach or the line runs unattended; manual and differential-pressure drains are available on other codes. The 40 um element is the standard grade; specify code W for 5 um where finer particulate removal matters. The fitted square gauge reads in psi; MPa or bar scales and an external round gauge are alternatives. PT is the standard thread and G (this code) or NPT are order options; brackets are optional (this code has none).

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a l/min, m3/h or SCFM number. Send us your line pressure, set pressure and air demand and we will confirm the flow curve and correct size from the datasheet on request.

The A in the code specifies an automatic drain, which ejects collected condensate by itself - the right choice where the unit sits high, is enclosed, or runs unattended. Manual-drain and differential-pressure-drain versions are available on other GFR codes if you prefer to drain on a schedule or tie draining to pressure drop.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C20AJF2G AirTAC Filter Regulator G3/4, Auto Drain

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C20AJF2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.