verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4

The AirTAC GFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$135.05 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4

The AirTAC GFR600 series combines water and particulate filtration with pressure regulation in a single body. This unit, GFR600C20ALJF3TK, is built for 3/4 in NPT ports and carries a 40 um filter element, an automatic drain, a low-pressure type regulator, an embedded square gauge scaled in bar, and a reverse/check valve. The size 600 bowl is aluminium alloy, the maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C, non-freezing. No mounting bracket is fitted (code J).

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, and can be ordered with manual or differential-pressure drains, a 5 um element (code W), gauge scales in MPa or psi, G (BSPP) or NPT threads, and a bracket where needed. Flow for this series is published as curves rather than a single rated figure, so ask us to confirm sizing and datasheet figures against your application before ordering.

GFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4 Technical Specifications

ModelGFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4 Is Used

factory

Bottling-line actuation supply

Point-of-use conditioning for 3/4 in ring-main drops feeding bottle-washer and capper cylinders, with the automatic drain clearing condensate from humid plant air without daily attention.

precision_manufacturing

Pneumatic press clamping circuit

Regulating clamp cylinders on a machining fixture at low setpoints, where the low-pressure type regulator and 40 um element suit the valve stack and hold the clamping circuit setting.

science

Spray-booth atomising air

Filtering and regulating atomising air to spray guns in a finishing booth, with the fitted check valve holding the regulator setting while the booth supply is switched off between shifts.

Is the GFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4 the Right Unit?

Size and port are the first choices: 200, 300, 400 and 600 step up in port and flow capacity, and this unit sits at the top of the range on 3/4 in NPT threads. Where a bowl is present you choose the drain: differential-pressure (the default), automatic (as fitted here) or manual. Filter grade is 40 um as standard or 5 um with code W. Units with a regulator take an embedded square gauge in MPa, psi or bar scales (bar here), and a reverse/check valve can be specified with code K. Thread is PT as standard, with G (BSPP) and NPT as order options; brackets are optional on the GF/GR/GL/GFR bodies.

Flow for the GFR series is published as curves, not a single rated number, so no rated flow is quoted here. Send us your application and we will confirm sizing and datasheet figures on request before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4 FAQ

AirTAC publishes flow for the GFR series as curves rather than a single rated figure, so we do not quote a rated flow number. Tell us your application and we will confirm the flow and datasheet figures on request before you order.

This unit carries code A, an automatic drain that discharges collected condensate without manual attention. The GFR family is also available with a differential-pressure drain (the default) or a manual drain (code M); tell us which suits your maintenance routine and we will confirm the exact configuration and its figures.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C20ALJF3TK AirTAC Filter Regulator NPT3/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C20ALJF3TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.