The AirTAC GFR600C20C2WT AirTAC Filter Regulator NPT3/4 5 um is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The AirTAC GFR600C20C2WT is a size 600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built with a 3/4 in NPT port, a 5 um filter element (code W, one step finer than the 40 um standard), a differential-pressure drain that bleeds condensate automatically as flow passes through, and an external round gauge reading in psi. The aluminium alloy bowl suits the larger 600 frame, and the unit is supplied with a mounting bracket. Maximum inlet pressure is 1.0 MPa (145 psi), the standard regulator adjusts from 0.15-0.9 MPa (20-130 psi), and the operating temperature range is -5 to 70 C (non-freezing).
This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, 40 um or 5 um filtration, embedded square or external round gauges in MPa, psi or bar scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | GFR600C20C2WT AirTAC Filter Regulator NPT3/4 5 um |
|---|---|
| Series | GFR600 filter regulator |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | Aluminium alloy |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR600 | G-series filter regulator, 600 body — sets the port range. |
|---|---|
| C2 | Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Mounting bracket included. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR600 · See datasheet · 40 µm |
|---|---|
| One size down | GFR400 |
| Add lubrication | GFC600-C2 (two-unit set) |
Feeds a filtered, regulated supply to the machine tool's pneumatic valves and clamps, with 5 um filtration protecting the spool surfaces and the psi gauge letting setters verify setpoint at the drop.
Installed at the header feeding cylinder-driven carton forming and sealing stations, where one body does the filtering and regulating for the whole line and the differential-pressure drain keeps condensate moving out during continuous running.
Conditions the bench supply for lab pneumatics and analytical instrumentation, where the 5 um grade, stable regulated pressure and a local psi readout support repeatable results day to day.
Size 600 with a 3/4 in port is the largest step in the GFR range, so start there when the line feeds several actuators or a high-demand header; step down to 300/400 if the port is smaller. The 5 um element (W) suits instruments, valves and coating work that tolerate less particulate than the 40 um standard. The differential-pressure drain is the set-and-forget choice for lines with steady flow; choose automatic or manual drain codes if the duty differs. This unit carries the round psi gauge (C2); square embedded gauges and MPa/bar scales are alternative codes. NPT is ordered with the T suffix, G (BSPP) with G; PT is the catalogue standard. A bracket is included. Flow is published only as curves, not a single rating, so send us your demand figures and we will confirm sizing against the datasheet before you order.
Quick checklist
The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
AirTAC publishes flow for the GFR family as curves, not as a single rated figure, so we do not quote a number here. Send us your line pressure and air demand and we will confirm the flow figures from the datasheet for this exact model before you order.
The W in the code selects the 5 um filter grade, one step finer than the 40 um standard. It is the usual choice for air going to valves, instruments and coating or sensing equipment that does not tolerate coarser particulate. If your duty is general plant air, the 40 um version of the same size is the alternative code.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.