verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C20F1WTK AirTAC Filter Regulator NPT3/4

The AirTAC GFR600C20F1WTK AirTAC Filter Regulator NPT3/4 is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$125.59 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C20F1WTK AirTAC Filter Regulator NPT3/4

The AirTAC GFR600C20F1WTK is a size 600 filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration is built with a 3/4 in NPT port, 5 um filtration (the finer of the two catalogue grades), a differential-pressure drain that bleeds collected condensate automatically as flow passes through, an embedded square pressure gauge scaled in MPa, and a reverse/check valve fitted to hold downstream pressure. The metal bowl on this size 600 unit is aluminium alloy, and the maximum working (inlet) pressure is 1.0 MPa (145 psi) with a standard regulation range of 0.15-0.9 MPa (20-130 psi). Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR family is published in sizes 200, 300, 400 and 600 with port sizes from 1/8 in to 1 in, a choice of 40 um or 5 um filtration, differential-pressure, automatic or manual drains, square or round gauges with MPa, psi or bar scales, G/NPT thread options, and an optional bracket. Flow is published in the catalogue as curves rather than a single rated figure, so ask us to confirm sizing or any datasheet figure for your application before ordering.

GFR600C20F1WTK AirTAC Filter Regulator NPT3/4 Technical Specifications

ModelGFR600C20F1WTK AirTAC Filter Regulator NPT3/4
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C20F1WTK AirTAC Filter Regulator NPT3/4

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C20F1WTK AirTAC Filter Regulator NPT3/4 Is Used

factory

Plant air main conditioning

Installed at the take-off of a factory compressed-air ring main, the unit strips water and particles to 5 um and sets a stable regulated pressure for the downstream distribution leg serving multiple workstations.

conveyor_belt

Packaging and conveyor lines

Feeding the air cylinders and actuators on a packaging or conveyor line, the regulator holds a constant working pressure so clamp and push strokes stay repeatable, while the 5 um grade protects valve spools from particulate.

valve

Pneumatic valve and actuator supply

Mounted ahead of solenoid valve manifolds and pneumatic actuators on process equipment, the unit delivers clean, regulated air, and the fitted check valve holds the downstream circuit pressurised if the upstream supply drops.

Is the GFR600C20F1WTK AirTAC Filter Regulator NPT3/4 the Right Unit?

Choose the size and port step against the air demand of the circuit: this unit is size 600 with a 3/4 in NPT port, the largest step in the GFR range, suited to lines with higher air consumption. Filtration here is the 5 um grade (code W) instead of the 40 um standard, so pick it where downstream valves, cylinders or instruments need finer particle removal; the differential-pressure drain handles condensate automatically, while automatic or manual drains are the other catalogue choices. The square MPa gauge is fitted, with psi or bar scales and an external round gauge available as options, and the reverse/check valve (code K) is fitted to prevent downstream pressure decay. Thread is NPT here; PT is the standard and G is also a catalogue option. A bracket is included for mounting.

Because flow is published as curves and not a single rated number, we cannot quote one figure here: send us your air demand and line conditions and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C20F1WTK AirTAC Filter Regulator NPT3/4 FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a l/min, m3/h or SCFM number. Send us your air demand and application details and we will confirm the sizing and the relevant datasheet figures on request.

The W in the code selects the 5 um filter element instead of the 40 um standard, giving finer particle removal for sensitive downstream components. The K code means a reverse/check valve is fitted, which prevents downstream pressure from bleeding back through the unit. Both are standard catalogue options on the GFR filter regulator.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C20F1WTK AirTAC Filter Regulator NPT3/4

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C20F1WTK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.