The AirTAC GFR600C20LJF1T AirTAC Filter Regulator 3/4 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$112.91 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C20LJF1T AirTAC Filter Regulator 3/4 in NPT

The AirTAC GFR600C20LJF1T is a 600-size filter regulator: it removes water and particulate from compressed air and regulates downstream pressure in a single body. This configuration has 3/4 in NPT ports, the standard 40 um filtration grade, a differential-pressure drain on the bowl, and a low-pressure regulator type with an embedded square gauge reading in MPa. The bowl on this 600 size is aluminium alloy, and the unit is supplied without a mounting bracket.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with port options from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, a 40 um standard or 5 um (W) filter grade, MPa, psi or bar gauge scales, and PT, G or NPT threads. Flow is published as curves rather than a single rating, so ask us to confirm the figures and datasheet for your application.

GFR600C20LJF1T AirTAC Filter Regulator 3/4 in NPT Technical Specifications

ModelGFR600C20LJF1T AirTAC Filter Regulator 3/4 in NPT
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C20LJF1T AirTAC Filter Regulator 3/4 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C20LJF1T AirTAC Filter Regulator 3/4 in NPT Is Used

factory

Automotive paint shop air supply

Point-of-use preparation ahead of spray booths and air-assisted guns, where water and dirt must be stripped out and the line held at a low, stable working pressure.

conveyor_belt

Carton-sealing conveyor cylinders

Feeding the flap-press and case-clamp cylinders on a packaging conveyor, with the 3/4 in port serving a larger header that supplies several stations.

science

Water-treatment plant valve actuators

Filtered, low-pressure regulated air for pneumatic quarter-turn actuators on process valves in a treatment or dosing skid.

Is the GFR600C20LJF1T AirTAC Filter Regulator 3/4 in NPT the Right Unit?

Start with the port step: this unit is the 600 size with 3/4 in NPT ports, the largest in the GFR range - step down to 200/300/400 with 1/8 in to 1/2 in ports if your line is smaller, and match the size to the flow your circuit needs. The drain here is differential-pressure (the default); automatic (A) or manual (M) drains are order options if you prefer. The 40 um element is standard; specify code W for the 5 um grade where finer filtration is required. The gauge is the embedded square type with an MPa scale, and psi or bar scales can be ordered instead. Thread is NPT here; PT is the standard thread and G (BSPP) is also a catalogue option. Bracket: this code carries no bracket (J).

One honest note on sizing: AirTAC publishes flow for this family as curves, not as a single rated figure, so send us your application details and we will confirm the flow and datasheet figures before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C20LJF1T AirTAC Filter Regulator 3/4 in NPT FAQ

AirTAC publishes flow for the GFR family as performance curves rather than a single rated figure, so we do not quote a number here. Tell us your line pressure and the flow your circuit needs, and we will confirm the sizing against the datasheet curves before you order.

The L code makes this a low-pressure regulator variant rather than the standard type; the exact adjustment range for the low-pressure version is not published in the sheet, so we confirm it on request. Drainage is the differential-pressure type (the default code), which bleeds the bowl automatically as flow passes; automatic (A) and manual (M) drains are available as order options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C20LJF1T AirTAC Filter Regulator 3/4 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C20LJF1T and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.