verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure

The AirTAC GFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$112.75 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure

The GFR600C20LJF2G is an AirTAC GFR-series filter regulator: water and particulate filtration plus downstream pressure regulation in a single body. This size 600 unit carries a G3/4 (3/4 in) female G-thread port, is built as the low-pressure regulator type, filters to the standard 40 um grade, and uses a differential-pressure drain that bleeds condensate automatically whenever the pressure differential across the element is high enough. The size 600 bowl is aluminium alloy, an embedded square gauge with psi scale is fitted, and no mounting bracket and no reverse/check valve are included in this configuration.

This is a genuine AirTAC part. The GFR family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, a choice of differential-pressure, automatic or manual drains, a 5 um optional element (code W), MPa, psi or bar gauge scales, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet for your application.

GFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure Technical Specifications

ModelGFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure Is Used

factory

Palletiser and case-packing air prep

On a palletiser line running large bore cylinders and grippers, this G3/4 filter regulator conditions the main supply: the 40 um element strips water and pipe scale, and the low-pressure regulator holds a gentle, stable working pressure so cartons are clamped without crushing.

conveyor_belt

Bottling line conveyor actuation

A washdown-adjacent bottling hall feeds stoppers, pushers and gate diverters from a 3/4 in ring main. This unit filters the humid plant air at the drop and regulates it down to the low pressure the conveyor actuators need, with the differential-pressure drain collecting condensate along the way.

science

Pneumatic test rig supply

A leak-test and pressure-test bench drawing from shop air uses this filter regulator at its G3/4 inlet to deliver clean, low-pressure air to the fixture circuit, with the fitted psi gauge giving the operator a direct readout of the regulated setpoint.

Is the GFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure the Right Unit?

Start with the port step: this unit is size 600 with a G3/4 (3/4 in) G-thread port, the largest in the GFR range - step down to sizes 200/300/400 if your circuit uses smaller ports, and match the size to the flow your line needs. Choose the drain next: this configuration uses the differential-pressure drain (default); specify automatic (A) for continuous condensate removal or manual (M) where you want to drain on a schedule. Filtration is the standard 40 um element; add code W for the 5 um grade if downstream valves or instruments need finer air. This is the low-pressure regulator type, so its exact adjustment range differs from the standard type - confirm the range with us before ordering if your setpoint is critical. The fitted square gauge reads in psi; MPa or bar scales and an external round gauge are alternatives. Threads come as PT (standard), G or NPT to order, and a mounting bracket can be added. Because flow is published as curves and not a single rated figure, send us your application details and we will confirm sizing from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated figure, so we do not quote a l/min, m3/h or SCFM number. Tell us your line pressure, setpoint and the flow your actuators need, and we will confirm the correct size against the datasheet curves on request.

The L in the code marks the low-pressure regulator variant, intended where the working setpoint sits below what the standard type is set up for. Its exact adjustment range is not published in the catalogue sheet we work from, so confirm your setpoint with us and we will verify the range from the datasheet before you order. The standard GFR type is available as an alternative.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C20LJF2G AirTAC Filter Regulator G3/4, Low-Pressure

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C20LJF2G and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.