verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GFR600 · Filter Regulator (filter + regulator in one body)

GFR600C25AC1TK AirTAC Filter Regulator 1 in NPT

The AirTAC GFR600C25AC1TK AirTAC Filter Regulator 1 in NPT is a genuine G-series filter regulator: water separation, 40 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has See datasheet ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$136.15 Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the GFR600C25AC1TK AirTAC Filter Regulator 1 in NPT

The GFR600C25AC1TK is an AirTAC GFR600 filter regulator: water and particulate filtration plus pressure regulation combined in a single body. This configuration is the size 600 unit with a 1 in NPT port, a 40 um standard filter element, an automatic drain that bleeds collected condensate from the bowl without manual attention, and an aluminium alloy bowl (size 600 bowls are metal; smaller GFR sizes use polycarbonate). A round pressure gauge with an MPa scale is fitted, a reverse/check valve is built in, and the mounting bracket is included. Maximum inlet pressure is 1.0 MPa (145 psi), the regulator adjustment range is 0.15-0.9 MPa (20-130 psi), and the working temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFR filter-regulator family is available in sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and can be ordered with a different drain type (manual, automatic or differential-pressure), a 5 um element (code W), alternative gauge scales (MPa, psi or bar), G (BSPP) or NPT threads in place of the PT standard, and with or without a bracket. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.

GFR600C25AC1TK AirTAC Filter Regulator 1 in NPT Technical Specifications

ModelGFR600C25AC1TK AirTAC Filter Regulator 1 in NPT
SeriesGFR600 filter regulator
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialAluminium alloy
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: GFR600C25AC1TK AirTAC Filter Regulator 1 in NPT

GFR600G-series filter regulator, 600 body — sets the port range.
C2Port size See datasheet. This body offers 20 = PT3/4", 25 = PT1".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR600 · See datasheet · 40 µm
One size downGFR400
Add lubricationGFC600-C2 (two-unit set)

Where the GFR600C25AC1TK AirTAC Filter Regulator 1 in NPT Is Used

factory

Automotive paint-shop air drops

At the drop feeding spray guns and air-assisted applicators on a paint line, the unit removes water and pipe scale from the compressed air and holds a steady regulated pressure, while the automatic drain clears condensate between shifts without an operator visit.

conveyor_belt

Bottling-line conveyor actuators

On a bottling or canning conveyor, the cylinders and air grippers that index, push and divert containers share one filtered, regulated supply; the 1 in NPT port suits a main header tap and the check valve holds the setting if upstream supply dips.

settings_input_component

CNC machining-cell pneumatic panel

On the pneumatic panel serving clamps, tool-change cylinders and chip-blowoff nozzles in a machining cell, the unit conditions the shop air and regulates it to the circuit's setting, with the round MPa gauge giving the operator a direct pressure readout.

Is the GFR600C25AC1TK AirTAC Filter Regulator 1 in NPT the Right Unit?

Start with the port and size step: GFR comes in sizes 200, 300, 400 and 600, and this unit is the largest, size 600, with a 1 in NPT port - step up a size when your line needs more flow capacity, and match the thread to your piping (PT is the standard; G/BSPP and NPT are orderable options, as on this NPT unit). Choose the drain: automatic (this unit) suits points you cannot visit often, manual suits attended stations, and the differential-pressure default drains only when the pressure drop warrants it. Choose the element grade: 40 um is standard, 5 um (code W) where finer protection is needed. Pick the gauge scale - MPa, psi or bar - and note the reverse/check valve (fitted here, code K) and the included bracket. Because flow is published as curves rather than a single rated figure, send us your application and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowl on the GFR600 suits harsher environments than a PC bowl. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.

GFR600C25AC1TK AirTAC Filter Regulator 1 in NPT FAQ

AirTAC publishes flow for the GFR series as curves, not as a single rated number, so we do not quote a figure here. Tell us your application and we will confirm the flow and datasheet figures for this 1 in NPT, size 600 unit on request before you order.

The A in the code specifies an automatic drain: condensate collected in the aluminium bowl is expelled without anyone opening it, which suits unattended or hard-to-reach installations. The same GFR600 unit can be ordered with a manual drain (code M) or the differential-pressure drain (blank) instead, and with a 5 um element (W), another gauge scale, or a G/BSPP thread in place of NPT.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for GFR600C25AC1TK AirTAC Filter Regulator 1 in NPT

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GFR600C25AC1TK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.