verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 4V Series · 5/3-way Solenoid Valve

AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W)

The AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with PT1/8 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Closed center
  • Port sizePT1/8
  • Effective area13.6 mm²
  • Flow (Cv)0.8
  • Series4V200
$53.63 $58.64Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 4V230C-06 stroke, mounting and version on one page All 4V230C-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W)

The 4V230C-06C-W is a 5/3-way double-solenoid valve with a closed center, built on the mid-size 4V200 body with 1/8" PT ports. With both coils de-energised the spool sits at center and blocks all five ports, so a double-acting cylinder connected to it keeps whatever position it was in - useful where a slide or clamp must pause mid-stroke under control. The -W suffix marks the external-pilot version: pilot air is fed through a separate external pilot port rather than tapped from the main supply, so spool shifting stays dependable even when line pressure runs low or the circuit operates at reduced pressure.

Flow capacity sits at an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08), the 5/3 rating for this body, with switching response at 0.05 s or faster. The AC110V coil draws 4.5 VA and wires into the built-in terminal box, and the whole assembly weighs 360 g. It is a natural match for double-acting cylinders in roughly the O32-50 mm bore range, carries an IP65 (DIN40050) enclosure, and accepts a manual override. The aluminum body can also mount on a base to build an integrated manifold valve group.

Closed-center stopping is not a load-holding or safety function: air leakage can let the cylinder creep, so add a pilot check valve or a mechanical brake where a load must be held.

AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W) Technical Specifications

ModelAirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W)
Series4V200 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Closed center
Port sizePT1/8
Exhaust portPT1/8
Effective area (Cv)13.6 mm² (Cv 0.8)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight360 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area13.6 mm²
Flow coefficientCv 0.8
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W)

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-06Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W) Is Used

precision_manufacturing

Mid-stroke clamping stations

A closed-center 5/3 stops a double-acting clamp cylinder partway and blocks both cylinder ports, holding the workpiece while downstream operations run. The external pilot keeps the spool shifting reliably even if main pressure dips during peak plant demand.

view_module

Multi-position packaging slides

Pushers and product stops on packaging lines often need a hold position rather than just extend/retract. At 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08) this valve pairs well with O32-50 mm bores, and the AC110V 4.5 VA coil suits standard control panels wired at the terminal box.

engineering

Low-pressure and vacuum-adjacent circuits

Where the main line cannot guarantee enough pressure to tap off internally for piloting, the -W external pilot supply lets the 4V230C-06C-W switch cleanly at 0.05 s response, keeping test rigs and low-pressure process actuators cycling.

Is the AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W) the Right Valve?

Choose this valve when the actuator must stop and stay put between signals - closed center is the right 5/3 choice for that, while exhaust center (30E) lets the cylinder drift free and pressure center (30P) presses both sides. If your bore is small and speed demand is light, the 4V100 at Cv 0.6 may suffice; if you need more flow for a larger bore or quicker cycle, step up to the 4V300 at Cv 1.65. The external-pilot -W version is the one to specify when supply pressure is low, unstable, or vacuum-adjacent - a standard internally-piloted valve can fail to shift there. Consider a manifold base if several valves share one footprint.

When replacing an existing unit, match five points exactly: body size (4V200), function code (30C for closed center), port and thread (1/8" PT - order a G-thread variant if your fittings are BSPP parallel), coil voltage (AC110V here), and electrical entry (terminal box, not the grommet lead). Confirm the -W external-pilot option as well, since it changes the porting layout.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W) FAQ

It directs compressed air to double-acting cylinders and actuators in the ~O32-50 mm bore range. As a 5/3-way valve its effective area is 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08), compared with 17.0 mm2 (Cv 1.0) for the 5/2 valves in the same 4V200 body, because the center-position flow paths reduce the through-flow. Maximum cycling frequency is 3 cycles per second versus 5 for the 5/2.

With neither coil energised, the closed center blocks all ports, so the cylinder holds its last position. Note the hold is functional, not a certified safety brake - for suspended or hazardous loads add a pilot-operated check valve at the cylinder ports or a mechanical brake. The -W option means pilot air comes from a separate external port instead of the main supply, so the spool still shifts reliably when line pressure is low or unstable.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC 4V230C-06 Solenoid Valve, 4V200 Series (4V230C06C-W)

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 4V230C06C-W and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.