The AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT1/4 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V230E08B-AM is a 5/3-way double-solenoid directional valve in the 4V200 body class, built here with a PT 1/4" (Rc tapered) port, a DC24V coil on a terminal-box entry, and the factory -AM option that swaps the standard coil for an AMISCO (Italian) solenoid. Because it is an exhaust-center (30E) valve, its center position vents both cylinder ports A and B to atmosphere while supply P is blocked - so the moment you de-energise both solenoids, a double-acting cylinder is left unpressurised on both sides and floats free. That makes this valve the right pick wherever a slide, lift or gripper must be movable by hand or by external force in the neutral state, rather than locked.
At the 5/3 flow level it offers an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08), a response time of 0.05 s or less and a maximum switching frequency of 3 cycles per second, which suits it to ~O32-50 mm bore double-acting cylinders in mid-duty machines. The valve weighs 360 g, carries an IP65 (DIN40050) rated coil section, runs on 0.15-0.8 MPa filtered air and needs no lubrication. Note that the AMISCO coil keeps the ordered DC24V voltage, but its exact electrical rating differs from the standard AirTAC coil, so confirm the VA/W figure with us before sizing your power supply.
| Model | AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | PT1/4 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
De-energise both coils and the stopper cylinder vents on both ports, letting product pass or operators reposition the gate by hand without venting plumbing.
Operators can slide or align a fixture cylinder by hand while the valve sits in its exhaust center, then snap it back under power with a short pulse to either coil.
Group several 4V230E08B-AM valves on a common base for packaging and testing panels where each axis must float free when idle.
Choose the 4V230E08B-AM when you specifically need the exhaust-center behaviour - a cylinder that drifts or can be repositioned when the valve sits in neutral. If the load must instead stay put in center, step to the closed-center 4V230C; if both cylinder sides should stay pressurised, pick the pressure-center 4V230P. For smaller bores the 4V100 (Cv 0.6) costs less, while larger or faster cylinders call for the 4V300 (Cv 1.65). A single valve on its own bracket suits standalone stations; mount several on a common base to build an integrated manifold group and slash the plumbing on multi-valve panels.
Ordering a replacement is a five-point match on this exact code: body size 4V200, function 30E (double solenoid, exhaust center), port plus thread 1/4" PT, coil voltage DC24V, and electrical entry terminal box. Keep the -AM suffix if your line standardises on AMISCO coils.
Quick checklist
It is a 5/3-way valve for double-acting cylinders and pneumatic actuators. With an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08) it comfortably serves ~O32-50 mm bores, switching up to 3 cycles per second with a response of 0.05 s or faster. Single-acting cylinders need a 3/2 valve, not this one.
This unit is a standard 4V230E-08B fitted at the factory with an AMISCO (Italian) solenoid coil instead of the AirTAC standard. Body, ports, flow and the ordered DC24V voltage are unchanged, but the coil's VA/W rating differs from our published 4V200 figures, so please confirm the exact AMISCO rating with us before specifying your 24 V power supply.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.