The AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT1/4 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/3-way
  • Function5/3 double solenoid — Exhaust center
  • Port sizePT1/4
  • Effective area13.6 mm²
  • Flow (Cv)0.8
  • Series4V200
$58.17 $63.30Save 8% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 4V230E-08 stroke, mounting and version on one page All 4V230E-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM)

The AirTAC 4V230E08B-AM is a 5/3-way double-solenoid directional valve in the 4V200 body class, built here with a PT 1/4" (Rc tapered) port, a DC24V coil on a terminal-box entry, and the factory -AM option that swaps the standard coil for an AMISCO (Italian) solenoid. Because it is an exhaust-center (30E) valve, its center position vents both cylinder ports A and B to atmosphere while supply P is blocked - so the moment you de-energise both solenoids, a double-acting cylinder is left unpressurised on both sides and floats free. That makes this valve the right pick wherever a slide, lift or gripper must be movable by hand or by external force in the neutral state, rather than locked.

At the 5/3 flow level it offers an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08), a response time of 0.05 s or less and a maximum switching frequency of 3 cycles per second, which suits it to ~O32-50 mm bore double-acting cylinders in mid-duty machines. The valve weighs 360 g, carries an IP65 (DIN40050) rated coil section, runs on 0.15-0.8 MPa filtered air and needs no lubrication. Note that the AMISCO coil keeps the ordered DC24V voltage, but its exact electrical rating differs from the standard AirTAC coil, so confirm the VA/W figure with us before sizing your power supply.

AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM) Technical Specifications

ModelAirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM)
Series4V200 solenoid valve (spool type)
Valve type5/3-way
Function5/3 double solenoid — Exhaust center
Port sizePT1/4
Exhaust portPT1/8
Effective area (Cv)13.6 mm² (Cv 0.8)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency3 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight360 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area13.6 mm²
Flow coefficientCv 0.8
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM)

4VSolenoid valve, spool type, 4-series.
2Body size (4V200) — sets port & flow.
3Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-08Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM) Is Used

conveyor_belt

Free-moving conveyor stops and gates

De-energise both coils and the stopper cylinder vents on both ports, letting product pass or operators reposition the gate by hand without venting plumbing.

precision_manufacturing

Assembly fixtures needing manual jog

Operators can slide or align a fixture cylinder by hand while the valve sits in its exhaust center, then snap it back under power with a short pulse to either coil.

settings_input_component

Manifold-mounted machine stations

Group several 4V230E08B-AM valves on a common base for packaging and testing panels where each axis must float free when idle.

Is the AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM) the Right Valve?

Choose the 4V230E08B-AM when you specifically need the exhaust-center behaviour - a cylinder that drifts or can be repositioned when the valve sits in neutral. If the load must instead stay put in center, step to the closed-center 4V230C; if both cylinder sides should stay pressurised, pick the pressure-center 4V230P. For smaller bores the 4V100 (Cv 0.6) costs less, while larger or faster cylinders call for the 4V300 (Cv 1.65). A single valve on its own bracket suits standalone stations; mount several on a common base to build an integrated manifold group and slash the plumbing on multi-valve panels.

Ordering a replacement is a five-point match on this exact code: body size 4V200, function 30E (double solenoid, exhaust center), port plus thread 1/4" PT, coil voltage DC24V, and electrical entry terminal box. Keep the -AM suffix if your line standardises on AMISCO coils.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM) FAQ

It is a 5/3-way valve for double-acting cylinders and pneumatic actuators. With an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08) it comfortably serves ~O32-50 mm bores, switching up to 3 cycles per second with a response of 0.05 s or faster. Single-acting cylinders need a 3/2 valve, not this one.

This unit is a standard 4V230E-08B fitted at the factory with an AMISCO (Italian) solenoid coil instead of the AirTAC standard. Body, ports, flow and the ordered DC24V voltage are unchanged, but the coil's VA/W rating differs from our published 4V200 figures, so please confirm the exact AMISCO rating with us before specifying your 24 V power supply.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC 4V230E-08 Solenoid Valve, 4V200 Series (4V230E08B-AM)

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 4V230E08B-AM and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.