The AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/4 ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V32008A-W is a 5/2-way double-solenoid directional valve in the 4V300 body class, built to direct compressed air to double-acting cylinders and actuators with a 1/4" PT (Rc tapered) port. Its twin-coil design gives the spool a memory: pulse one solenoid and the spool shifts, then simply stays in that last-pulsed position through land friction and balanced pressure - no spring moves it and no holding current is drawn. It is not magnetically latched; the hold is purely mechanical.
What sets this SKU apart is the factory -W external-pilot option: pilot air is fed through a separate external port rather than tapped internally from the main supply, so the valve still shifts dependably when main-line pressure runs low or on vacuum and low-pressure circuits. The 5/2 flow path offers a 28 mm² effective area (Cv 1.65) for bore sizes around O50-80 mm, switching at up to 4 cycles per second with a response of 0.05 s or better. This version carries an AC220V coil drawing 4.5 VA on a terminal-box entry, and the complete valve weighs 400 g.
| Model | AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/4 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
The external pilot keeps the spool shifting on diverters and gate cylinders fed from a low-pressure or vacuum main, where an internally piloted valve would stall.
A short pulse to either coil clamps or releases a double-acting clamp cylinder on an O50-80 mm bore, and the memory holds the state without continuous coil power.
Cv 1.65 (catalog figure for the 4V310-10) flow and a response of 0.05 s or below suit stroke and positioning actuators on machine tools running 220 V AC control circuits with terminal wiring.
Size the 4V300 class by bore: drop to the 4V200 (Cv 1.0) for small cylinders, stay here for roughly O50-80 mm bores, and step up to the 4V400 (Cv 2.82) when larger actuator areas need more flow. Choose a double solenoid like this when you need the actuator to stay put after a pulse ends; pick a single-solenoid 5/2 (function 10) when it must spring back on signal loss, or a 5/3 center type when mid-stroke behavior matters. Mount on an individual base or build an integrated manifold group for multi-valve stations.
Ordering a replacement means matching five points: body size (4V300), function (20 double solenoid), port and thread (1/4" PT - G or NPT variants exist), coil voltage (here AC220V), and electrical entry (terminal box, not the grommet lead). Confirm the -W external-pilot suffix too, since it changes the plumbing.
Quick checklist
It directs air to double-acting cylinders and actuators around the O50-80 mm bore class, with a 28 mm² effective area (Cv 1.65) on the 1/4" PT port. The -W suffix means external pilot: pilot air comes from a separate port, so switching stays reliable when main-line pressure is low or in vacuum circuits.
Yes. After the last pulse, the spool remains where it was shifted, held by land friction and balanced pressure with no holding current - there is no magnet in the design. For suspended or fall-risk loads, add a pilot-operated check valve at the cylinder ports or a mechanical brake rather than relying on the valve alone.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.