AirTAC 4V Series · 5/2-way Solenoid Valve

AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W)

The AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/4 ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionDouble solenoid (memory)
  • Port sizePT1/4
  • Effective area28.0 mm²
  • Flow (Cv)1.65
  • Series4V300
$60.43 $65.62Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every 4V320-08 stroke, mounting and version on one page All 4V320-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W)

The AirTAC 4V32008A-W is a 5/2-way double-solenoid directional valve in the 4V300 body class, built to direct compressed air to double-acting cylinders and actuators with a 1/4" PT (Rc tapered) port. Its twin-coil design gives the spool a memory: pulse one solenoid and the spool shifts, then simply stays in that last-pulsed position through land friction and balanced pressure - no spring moves it and no holding current is drawn. It is not magnetically latched; the hold is purely mechanical.

What sets this SKU apart is the factory -W external-pilot option: pilot air is fed through a separate external port rather than tapped internally from the main supply, so the valve still shifts dependably when main-line pressure runs low or on vacuum and low-pressure circuits. The 5/2 flow path offers a 28 mm² effective area (Cv 1.65) for bore sizes around O50-80 mm, switching at up to 4 cycles per second with a response of 0.05 s or better. This version carries an AC220V coil drawing 4.5 VA on a terminal-box entry, and the complete valve weighs 400 g.

AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W) Technical Specifications

ModelAirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W)
Series4V300 solenoid valve (spool type)
Valve type5/2-way
FunctionDouble solenoid (memory)
Port sizePT1/4
Exhaust portPT1/4
Effective area (Cv)28.0 mm² (Cv 1.65)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency4 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight400 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area28.0 mm²
Flow coefficientCv 1.65
Response time≤ 0.05 s
Coil powerAC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W)

4VSolenoid valve, spool type, 4-series.
3Body size (4V300) — sets port & flow.
2Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-08Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W) Is Used

conveyor_belt

Low-pressure conveying gates

The external pilot keeps the spool shifting on diverters and gate cylinders fed from a low-pressure or vacuum main, where an internally piloted valve would stall.

bolt

Pulsed clamping fixtures

A short pulse to either coil clamps or releases a double-acting clamp cylinder on an O50-80 mm bore, and the memory holds the state without continuous coil power.

precision_manufacturing

Machine-tool actuators

Cv 1.65 (catalog figure for the 4V310-10) flow and a response of 0.05 s or below suit stroke and positioning actuators on machine tools running 220 V AC control circuits with terminal wiring.

Is the AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W) the Right Valve?

Size the 4V300 class by bore: drop to the 4V200 (Cv 1.0) for small cylinders, stay here for roughly O50-80 mm bores, and step up to the 4V400 (Cv 2.82) when larger actuator areas need more flow. Choose a double solenoid like this when you need the actuator to stay put after a pulse ends; pick a single-solenoid 5/2 (function 10) when it must spring back on signal loss, or a 5/3 center type when mid-stroke behavior matters. Mount on an individual base or build an integrated manifold group for multi-valve stations.

Ordering a replacement means matching five points: body size (4V300), function (20 double solenoid), port and thread (1/4" PT - G or NPT variants exist), coil voltage (here AC220V), and electrical entry (terminal box, not the grommet lead). Confirm the -W external-pilot suffix too, since it changes the plumbing.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W) FAQ

It directs air to double-acting cylinders and actuators around the O50-80 mm bore class, with a 28 mm² effective area (Cv 1.65) on the 1/4" PT port. The -W suffix means external pilot: pilot air comes from a separate port, so switching stays reliable when main-line pressure is low or in vacuum circuits.

Yes. After the last pulse, the spool remains where it was shifted, held by land friction and balanced pressure with no holding current - there is no magnet in the design. For suspended or fall-risk loads, add a pilot-operated check valve at the cylinder ports or a mechanical brake rather than relying on the valve alone.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for AirTAC 4V320-08 Solenoid Valve, 4V300 Series (4V32008A-W)

Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for 4V32008A-W and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.