The AirTAC 4V330E-08F Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC12V, terminal entry (4V330E08F) is a genuine 5/3-way 5/3 double solenoid — exhaust center solenoid valve with PT1/4 ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330E-08F is a 5/3-way pneumatic solenoid valve that directs compressed air to double-acting cylinders and actuators, adding a third center position that exhausts both cylinder ports. When neither solenoid is energized, the spool moves to its mid-position, venting pressure from the A and B ports to atmosphere. This allows the attached cylinder to float freely, making the valve ideal for applications where a load needs to be manually repositioned or where pressure must be fully released during an emergency stop cycle.
Built on the 4V300 aluminum-alloy body with 1/4-inch PT (Rc) tapered threads, this model carries a DC12V coil drawing just 2.5 W of power. Its 5/3 spool provides an effective area of 21.3 mm² (Cv 1.25, catalog figure for the 4V330C-10) and cycles at up to 3 times per second. With a response time of 0.05 seconds or less and IP65 protection, it delivers reliable mid-stop control for bore sizes roughly in the O50 to O80 mm range.
| Model | AirTAC 4V330E-08F Solenoid Valve, 5/3-way, exhaust center, PT1/4, DC12V, terminal entry (4V330E08F) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Exhaust center |
| Port size | PT1/4 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
In ergonomic lift-assist arms, the exhaust center allows operators to manually guide a double-acting cylinder to the exact height or angle needed before re-engaging pneumatic power.
For fixtures that clamp a part pneumatically but require a manual unload step, the 4V330E-08F dumps air from the clamp cylinder at center, letting the operator slide the finished piece out freely.
In safety-rated E-stop sequences, this valve's exhaust center rapidly vents both sides of a cylinder, removing stored energy and preventing unintended movement when power is cut.
Choose the 4V330E-08F when your pneumatic circuit requires a double-acting cylinder to go completely limp at center—common in manual load-assist or clamping setups where the tool must be freely moved by hand. This 5/3 exhaust-center configuration is distinct from the closed-center 4V330C (which blocks all ports to hold position) and the pressure-center 4V330P (which applies pressure to both sides). If your cylinder bore is under O50 mm, the smaller 4V200 series (Cv 1.0) may be a better fit; for bores above O80 mm, step up to the 4V400 series (Cv 2.82) for higher flow.
When replacing an existing valve, match five points exactly: body size (4V300), function (5/3 exhaust center), port size and thread (1/4-inch PT), coil voltage (DC12V), and electrical entry (terminal box). This valve can be mounted individually or ganged on a manifold base for multi-cylinder systems.
AirtacDistr lists every 4V330E-08 order code with its price on one page at https://airtacdistr.com/products/airtac-4v330e-08-solenoid-valve
Quick checklist
In the center position (both solenoids off), the valve connects both cylinder ports (A and B) to the exhaust ports, allowing air to escape. This means a double-acting cylinder attached to it will not hold position but will float freely, which is useful for manual positioning or safety venting.
No, this specific model (4V330E-08F) has a 3.0 W DC12V coil. Applying 24V will burn out the coil. For a 24V DC system, select the 4V330E-08B variant instead. Always match the valve's rated voltage to your power supply.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, coil voltage and destination. We confirm price, availability and lead time — usually within 7 hours.