The AirTAC AirTAC 4V320-08F Solenoid Valve, 5/2-way, PT1/4, DC12V, terminal entry (4V32008F) is a genuine 5/2-way double solenoid (memory) solenoid valve with 32008F ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V320-08F is a 5/2-way double-solenoid pneumatic directional valve built on the 4V300 aluminum body platform. It directs compressed air to double-acting cylinders and actuators, and its memory function means the spool stays locked in the last pulsed position when electrical power is removed—no spring return, no holding current. This makes it ideal for circuits where the actuator must hold its end-of-stroke position during an E-stop or power cycle, though a pilot-operated check valve is still required for true load-holding safety.
With 1/4-inch PT (Rc) ports and a DC12V coil drawing just 2.5 W, this valve suits compact mobile or battery-powered pneumatic systems. The sliding-column spool delivers an effective area of 28.0 mm² (Cv 1.65) and a maximum cycling rate of 4 cycles per second. Response time is 0.05 seconds or less, and the IP65-rated terminal-box entry keeps the wiring protected in dusty or wet environments. At 400 grams, it’s a robust yet manageable choice for machine builders.
| Model | AirTAC 4V320-08F Solenoid Valve, 5/2-way, PT1/4, DC12V, terminal entry (4V32008F) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | 32008F |
| Exhaust port | 32008F |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -32008F | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
The memory function holds clamp or pusher cylinders in place during a power interruption, preventing product damage on a palletizer or case packer. The 4 c/s max frequency keeps up with moderate-speed packaging lines.
A double-solenoid 5/2 valve ensures a fixture clamp stays engaged when the machine E-stops. The 1/4-inch ports and Cv 1.65 provide ample flow for medium-bore clamping cylinders.
The 2.5 W DC12V coil draws minimal current from a vehicle or battery supply. Use it to control gate or chute actuators on agricultural or construction equipment where wiring simplicity matters.
Choose the 4V320-08F when your application needs a 5/2 valve that remembers its last state without continuous power—perfect for energy-sensitive or safety-conscious circuits. The 1/4-inch port size and 28.0 mm² effective area suit double-acting cylinders roughly in the Ø50–80 mm range. If you’re driving a smaller cylinder (Ø32–40 mm), the 4V200 series (Cv 1.0) may be a better fit; for larger bores above Ø100 mm, step up to the 4V400 (Cv 2.82) for faster fill times.
When replacing an existing valve, match these five points exactly: body size (4V300), function (4V320 double-solenoid memory), port and thread (1/4-inch PT), coil voltage (DC12V), and electrical entry (terminal box). This valve can be used as a single unit or ganged on a manifold base—the manifold option simplifies plumbing for multi-cylinder stations. The DC12V coil is less common than DC24V, so verify your power supply before ordering.
Quick checklist
The double-solenoid spool stays in its last commanded position—it does not spring back. The cylinder will hold its current state until the opposite solenoid is pulsed. This is a mechanical memory hold, not a magnetic latch. For suspended loads, always add a pilot-operated check valve.
Yes, the ‘F’ voltage code is specifically for DC12V coils. Power consumption is 2.5 W, so it’s well-suited to mobile or off-grid pneumatic setups. Just ensure your supply can handle the inrush when the coil energizes.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.