Every stocked AirTAC DS1-A switch on one page: 16 order codes, from $15.78. Pick the type and connection to see the exact order code and price.
Fits SC (all bores)
This combination is not a stock order code. Request a quote and we will confirm availability and price.
The AirTAC DS1-A is a solid-state cylinder switch for SC (all bores) cylinders: its transistor output turns on when the piston magnet passes. With no moving contact it switches up to 1000 times per second and has reverse polarity and surge protection. A red LED shows when it is on.
It fits AirTAC SC (all bores) cylinders. It is rated IP67 (NEMA 6) and works at -10 to +70 °C.
| Model | DS1-A |
|---|---|
| Fits | SC (all bores) |
| Output | Transistor, normally open |
| 2-wire | 10 – 28 V DC, 50 mA max., 1.4 W max. |
| 2-wire voltage drop / leakage | 2.65 V max. at 50 mA / 20 (90) µA max. at 28 V |
| 2-wire cable | Ø3.3 mm, 2-core, black oil-resistant PVC |
| 3-wire NPN / PNP | 5 – 30 V DC, 200 mA max., 6 W max. |
| 3-wire current consumption | 15 mA max. at 24 V |
| 3-wire voltage drop | 0.5 V max. at 200 mA |
|---|---|
| 3-wire cable | Ø3.3 mm, 3-core, black oil-resistant PVC |
| Indicator | Red LED |
| Max. switching frequency | 1000 Hz |
| Shock / vibration | 500 / 90 m/s² |
| Protection circuit | Reverse polarity, surge |
| Sensitivity | 2-wire 25 – 700; 3-wire 60 – 75 gauss |
| Temperature | -10 to +70 °C |
| Protection | IP67 (NEMA 6) |
Source: AirTAC catalog, DS1-A solid-state switch specifications and ordering code.
| DS1 | Solid-state (electronic) switch |
|---|---|
| A | Model |
| blank / N / P | Type: blank = 2-wire; N = 3-wire NPN; P = 3-wire PNP |
| 020 / 030 / 050 / 100 / C08 / C12 | Connection: 2 m lead (020); 3 m lead (030); 5 m lead (050); 10 m lead (100); M8 connector, 150 mm lead (C08); M12 connector, 150 mm lead (C12) |
Each order code links to its own datasheet page. Use Select to load it into the configurator above.
| Order code | Type | Connection | Fits | Price | Select |
|---|---|---|---|---|---|
| DS1A020 | 2-wire | 2 m lead (020) | Fits SC (all bores) | $15.78 | |
| DS1A030 | 2-wire | 3 m lead (030) | Fits SC (all bores) | $22.19 | |
| DS1A050 | 2-wire | 5 m lead (050) | Fits SC (all bores) | $27.21 | |
| DS1A100 | 2-wire | 10 m lead (100) | Fits SC (all bores) | $32.74 | |
| DS1AC08 | 2-wire | M8 connector, 150 mm lead (C08) | Fits SC (all bores) | $18.83 | |
| DS1AN020 | 3-wire NPN (N) | 2 m lead (020) | Fits SC (all bores) | $20.43 | |
| DS1AN030 | 3-wire NPN (N) | 3 m lead (030) | Fits SC (all bores) | $21.37 | |
| DS1AN050 | 3-wire NPN (N) | 5 m lead (050) | Fits SC (all bores) | $23.23 | |
| DS1AN100 | 3-wire NPN (N) | 10 m lead (100) | Fits SC (all bores) | $27.88 | |
| DS1ANC08 | 3-wire NPN (N) | M8 connector, 150 mm lead (C08) | Fits SC (all bores) | $23.48 | |
| DS1AP020 | 3-wire PNP (P) | 2 m lead (020) | Fits SC (all bores) | $20.43 | |
| DS1AP030 | 3-wire PNP (P) | 3 m lead (030) | Fits SC (all bores) | $21.37 | |
| DS1AP050 | 3-wire PNP (P) | 5 m lead (050) | Fits SC (all bores) | $23.23 | |
| DS1AP100 | 3-wire PNP (P) | 10 m lead (100) | Fits SC (all bores) | $27.88 | |
| DS1APC08 | 3-wire PNP (P) | M8 connector, 150 mm lead (C08) | Fits SC (all bores) | $23.48 | |
| DS1APC12 | 3-wire PNP (P) | M12 connector, 150 mm lead (C12) | Fits SC (all bores) | $24.88 |
Need a combination that is not listed? Request a quote.
Signals when the piston reaches either end, so the next step can start.
Slide the switch along the barrel to detect any intermediate position.
Wires straight to a PLC input or relay with two or three wires.
Choose the output: 2-wire; 3-wire NPN (N); 3-wire PNP (P). The 2-wire type runs on 10 to 28 V DC at up to 50 mA and connects like a reed switch; the 3-wire NPN (sinking) and PNP (sourcing) types run on 5 to 30 V DC at up to 200 mA. Match NPN or PNP to your PLC input.
Choose the connection: 2 m lead (020); 3 m lead (030); 5 m lead (050); 10 m lead (100); M8 connector, 150 mm lead (C08); M12 connector, 150 mm lead (C12). The C08 and C12 versions end in a 3-pin male straight connector; the mating female cable is ordered separately.
AirTAC SC (all bores) cylinders.
2-wire: 10 to 28 V DC, up to 50 mA. 3-wire NPN or PNP: 5 to 30 V DC, up to 200 mA.
A 150 mm lead ending in an M8 (C08) or M12 (C12) 3-pin male connector. The female cable is ordered separately. 020, 030, 050 and 100 are fixed leads of 2, 3, 5 and 10 m.
The 2-wire type wires like a reed switch in series with the load. The 3-wire types need a separate supply and give an NPN (N) or PNP (P) transistor output with a lower voltage drop and higher current.
No. You can order a single piece. Orders are processed and handed to the carrier within 3-5 business days.
Every order code on this page is the AirTAC factory part number. Specifications follow the AirTAC Products Catalog 2026A. About us
That is our time to process the order and hand it to the carrier. No minimum order: a single piece can be ordered.
Return within 14 days of delivery; the buyer pays return shipping. The warranty covers defects not caused by misuse. Return policy
Send your application details and we will confirm the right order code, usually within 7-8 hours. Ask us
Page data checked against the live catalog on 2026-11-11.
Send the order code, quantity and destination. We confirm price, stock and lead time, usually within 7-8 hours.