verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC DPS Series · Digital Pressure Sensor

AirTAC DPS Digital Pressure Sensor, NPN or PNP, -100 to 1,000 kPa

Every listed AirTAC DPS pressure sensor on one page: 24 order codes from $48.82. Pick the output, pressure range and connection to see the exact order code and price.

Order code DPSN1-10020 Full DPSN1-10020 datasheet

This combination is not a stock order code. Request a quote and we will confirm availability and price.

$48.82 $56.32Save 13%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.

About the AirTAC DPS

The AirTAC DPS is an electronic pressure sensor with a digital display and two switch outputs. The two-line LCD shows the measured pressure on four digits and the set value on 3.5 digits, in red or green, and each output can work in simple, hysteresis or window mode. It measures -100 to 100 kPa and -100 to 1,000 kPa on non-corrosive gases and runs on 12-24 VDC.

Accuracy is ±2% of full scale ±1 digit and repeatability ±0.2% of full scale. Response time is selectable from 2 ms to 5 s and the display update from 100 ms to 1 s. Outputs are NPN (N1) or PNP (P1), up to 30 V and 100 mA each. The pressure port is a PT1/8 male thread with an M5 female thread inside, so it fits either way.

DPS Technical Specifications

ModelDPS
Supply12 – 24 VDC ±10%, ripple under 10%
FluidNon-corrosive gas
Range 01-100 to 100 kPa · proof 200 kPa · hysteresis 0.1-0.8 kPa
Range 10-100 to 1,000 kPa · proof 1,500 kPa · hysteresis 1-8 kPa
Accuracy±2% F.S. ±1 digit (25 ±3 °C)
Repeatability±0.2% F.S.
Temperature effect±3% F.S. (25 °C reference, 0 to 50 °C)
Outputs2 × NPN (N1) or 2 × PNP (P1), max 30 V / 100 mA, residual under 1.5 V
DisplayTwo-line LCD, 4-digit value, 3.5-digit setting, red/green
Display update100, 250, 500, 1000 ms
Response time2, 20, 50, 100, 250, 500, 1000, 2500, 5000 ms
Output modesSimple, hysteresis, window
Pressure portPT1/8 male + M5 female (G: G1/8 + M5; T: NPT1/8 + 10-32UNF)
Operating temperature0 to 50 °C (storage -20 to 65 °C)
Humidity35 – 85% RH
Vibration / shock10-150 Hz, 1.5 mm, 2 h per axis / 100 m/s², 3 times per axis
Rear cable exitIP63

Source: AirTAC Products Catalog 2026A (PDF01-P0279), DPS series specifications and ordering code.

How the DPS Order Code Is Built

DPSDigital pressure sensor
N1 / P1Output: two NPN / two PNP
blank / B / DConnection: terminal, rear cable, bottom cable
-01 / -10Range: -100 to 100 kPa / -100 to 1,000 kPa
020 / 030 / 050 / M08Cable 2 / 3 / 5 m; M08 = M8 male connector + 300 mm (rear exit only)
G / TPort: G = G1/8 + M5, T = NPT1/8 + 10-32UNF, blank = PT1/8 + M5

All AirTAC DPS Order Codes (24)

Each order code links to its own datasheet page. Use Select to load it into the configurator above.

Order codeOutputRangeConnectionPriceSelect
DPSN1-01020NPN, two outputs (N1)-100 to 100 kPa (01)Terminal connection, 2 m$48.82
DPSN1-01030NPN, two outputs (N1)-100 to 100 kPa (01)Terminal connection, 3 m$50.00
DPSN1-01050NPN, two outputs (N1)-100 to 100 kPa (01)Terminal connection, 5 m$52.33
DPSN1B-01020NPN, two outputs (N1)-100 to 100 kPa (01)Rear cable (B), 2 m$53.47
DPSN1B-01030NPN, two outputs (N1)-100 to 100 kPa (01)Rear cable (B), 3 m$54.66
DPSN1B-01050NPN, two outputs (N1)-100 to 100 kPa (01)Rear cable (B), 5 m$56.98
DPSN1-10020NPN, two outputs (N1)-100 to 1,000 kPa (10)Terminal connection, 2 m$48.82
DPSN1-10030NPN, two outputs (N1)-100 to 1,000 kPa (10)Terminal connection, 3 m$50.00
DPSN1-10050NPN, two outputs (N1)-100 to 1,000 kPa (10)Terminal connection, 5 m$52.33
DPSN1B-10020NPN, two outputs (N1)-100 to 1,000 kPa (10)Rear cable (B), 2 m$53.47
DPSN1B-10030NPN, two outputs (N1)-100 to 1,000 kPa (10)Rear cable (B), 3 m$54.66
DPSN1B-10050NPN, two outputs (N1)-100 to 1,000 kPa (10)Rear cable (B), 5 m$56.98
DPSP1-01020PNP, two outputs (P1)-100 to 100 kPa (01)Terminal connection, 2 m$48.82
DPSP1-01030PNP, two outputs (P1)-100 to 100 kPa (01)Terminal connection, 3 m$50.00
DPSP1-01050PNP, two outputs (P1)-100 to 100 kPa (01)Terminal connection, 5 m$52.33
DPSP1B-01020PNP, two outputs (P1)-100 to 100 kPa (01)Rear cable (B), 2 m$53.47
DPSP1B-01030PNP, two outputs (P1)-100 to 100 kPa (01)Rear cable (B), 3 m$54.66
DPSP1B-01050PNP, two outputs (P1)-100 to 100 kPa (01)Rear cable (B), 5 m$56.98
DPSP1-10020PNP, two outputs (P1)-100 to 1,000 kPa (10)Terminal connection, 2 m$48.82
DPSP1-10030PNP, two outputs (P1)-100 to 1,000 kPa (10)Terminal connection, 3 m$50.00
DPSP1-10050PNP, two outputs (P1)-100 to 1,000 kPa (10)Terminal connection, 5 m$52.33
DPSP1B-10020PNP, two outputs (P1)-100 to 1,000 kPa (10)Rear cable (B), 2 m$53.47
DPSP1B-10030PNP, two outputs (P1)-100 to 1,000 kPa (10)Rear cable (B), 3 m$54.66
DPSP1B-10050PNP, two outputs (P1)-100 to 1,000 kPa (10)Rear cable (B), 5 m$56.98

Need a combination that is not listed? Request a quote.

Where the DPS Is Used

Supply pressure monitoring

Signals the PLC when the line pressure drops below the set point.

Vacuum confirmation

The 01 range checks that a suction cup has picked the part.

Process windows

Window mode switches only while the pressure is inside a set band.

Choosing the Right DPS Configuration

Choose the output to match your PLC input: N1 gives two NPN outputs, P1 two PNP outputs.

Then the pressure range: 01 measures -100 to 100 kPa (vacuum and low pressure, proof 200 kPa), 10 measures -100 to 1,000 kPa (compressed air, proof 1,500 kPa).

Then the connection: no letter is the terminal connection, B the rear cable exit (IP63), D the bottom cable exit; the cable is 2, 3 or 5 m (020, 030, 050). The rear-exit version also comes with an M8 male connector on a 300 mm lead (M08), for the separate F-ECM08D cable.

AirTAC DPS FAQ

Pick the one your controller input expects: N1 has two NPN outputs, P1 two PNP outputs. Each is rated 30 V, 100 mA, with less than 1.5 V residual voltage.

01 for vacuum and low pressure (-100 to 100 kPa), 10 for compressed air (-100 to 1,000 kPa).

Range 01: kPa, kgf/cm², bar, psi, mmHg, inHg. Range 10: MPa, kPa, kgf/cm², bar, psi, cmHg, inHg.

0 to 50 °C, 35 to 85% RH without condensation, 12-24 VDC ±10% with less than 10% ripple.

No. You can order a single piece. Orders are processed and handed to the carrier within 3-5 business days.

Buying the DPS from AirtacDistr

Genuine AirTAC parts

Every order code on this page is the AirTAC factory part number. Specifications follow the AirTAC Products Catalog 2026A. About us

Ready in 3-5 business days

That is our time to process the order and hand it to the carrier. No minimum order: a single piece can be ordered.

14-day returns, 1-year warranty

Return within 14 days of delivery; the buyer pays return shipping. The warranty covers defects not caused by misuse. Return policy

Engineering help

Send your application details and we will confirm the right order code, usually within 7-8 hours. Ask us

Page data checked against the live catalog on 2026-11-12.

Request a Quote for the DPS

Send the order code, quantity and destination. We confirm price, stock and lead time, usually within 7-8 hours.

Thank you. We received your request for DPSN1-10020 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.