Every listed AirTAC DPS pressure sensor on one page: 24 order codes from $48.82. Pick the output, pressure range and connection to see the exact order code and price.
This combination is not a stock order code. Request a quote and we will confirm availability and price.
The AirTAC DPS is an electronic pressure sensor with a digital display and two switch outputs. The two-line LCD shows the measured pressure on four digits and the set value on 3.5 digits, in red or green, and each output can work in simple, hysteresis or window mode. It measures -100 to 100 kPa and -100 to 1,000 kPa on non-corrosive gases and runs on 12-24 VDC.
Accuracy is ±2% of full scale ±1 digit and repeatability ±0.2% of full scale. Response time is selectable from 2 ms to 5 s and the display update from 100 ms to 1 s. Outputs are NPN (N1) or PNP (P1), up to 30 V and 100 mA each. The pressure port is a PT1/8 male thread with an M5 female thread inside, so it fits either way.
| Model | DPS |
|---|---|
| Supply | 12 – 24 VDC ±10%, ripple under 10% |
| Fluid | Non-corrosive gas |
| Range 01 | -100 to 100 kPa · proof 200 kPa · hysteresis 0.1-0.8 kPa |
| Range 10 | -100 to 1,000 kPa · proof 1,500 kPa · hysteresis 1-8 kPa |
| Accuracy | ±2% F.S. ±1 digit (25 ±3 °C) |
| Repeatability | ±0.2% F.S. |
| Temperature effect | ±3% F.S. (25 °C reference, 0 to 50 °C) |
| Outputs | 2 × NPN (N1) or 2 × PNP (P1), max 30 V / 100 mA, residual under 1.5 V |
| Display | Two-line LCD, 4-digit value, 3.5-digit setting, red/green |
|---|---|
| Display update | 100, 250, 500, 1000 ms |
| Response time | 2, 20, 50, 100, 250, 500, 1000, 2500, 5000 ms |
| Output modes | Simple, hysteresis, window |
| Pressure port | PT1/8 male + M5 female (G: G1/8 + M5; T: NPT1/8 + 10-32UNF) |
| Operating temperature | 0 to 50 °C (storage -20 to 65 °C) |
| Humidity | 35 – 85% RH |
| Vibration / shock | 10-150 Hz, 1.5 mm, 2 h per axis / 100 m/s², 3 times per axis |
| Rear cable exit | IP63 |
Source: AirTAC Products Catalog 2026A (PDF01-P0279), DPS series specifications and ordering code.
| DPS | Digital pressure sensor |
|---|---|
| N1 / P1 | Output: two NPN / two PNP |
| blank / B / D | Connection: terminal, rear cable, bottom cable |
| -01 / -10 | Range: -100 to 100 kPa / -100 to 1,000 kPa |
| 020 / 030 / 050 / M08 | Cable 2 / 3 / 5 m; M08 = M8 male connector + 300 mm (rear exit only) |
| G / T | Port: G = G1/8 + M5, T = NPT1/8 + 10-32UNF, blank = PT1/8 + M5 |
Each order code links to its own datasheet page. Use Select to load it into the configurator above.
| Order code | Output | Range | Connection | Price | Select |
|---|---|---|---|---|---|
| DPSN1-01020 | NPN, two outputs (N1) | -100 to 100 kPa (01) | Terminal connection, 2 m | $48.82 | |
| DPSN1-01030 | NPN, two outputs (N1) | -100 to 100 kPa (01) | Terminal connection, 3 m | $50.00 | |
| DPSN1-01050 | NPN, two outputs (N1) | -100 to 100 kPa (01) | Terminal connection, 5 m | $52.33 | |
| DPSN1B-01020 | NPN, two outputs (N1) | -100 to 100 kPa (01) | Rear cable (B), 2 m | $53.47 | |
| DPSN1B-01030 | NPN, two outputs (N1) | -100 to 100 kPa (01) | Rear cable (B), 3 m | $54.66 | |
| DPSN1B-01050 | NPN, two outputs (N1) | -100 to 100 kPa (01) | Rear cable (B), 5 m | $56.98 | |
| DPSN1-10020 | NPN, two outputs (N1) | -100 to 1,000 kPa (10) | Terminal connection, 2 m | $48.82 | |
| DPSN1-10030 | NPN, two outputs (N1) | -100 to 1,000 kPa (10) | Terminal connection, 3 m | $50.00 | |
| DPSN1-10050 | NPN, two outputs (N1) | -100 to 1,000 kPa (10) | Terminal connection, 5 m | $52.33 | |
| DPSN1B-10020 | NPN, two outputs (N1) | -100 to 1,000 kPa (10) | Rear cable (B), 2 m | $53.47 | |
| DPSN1B-10030 | NPN, two outputs (N1) | -100 to 1,000 kPa (10) | Rear cable (B), 3 m | $54.66 | |
| DPSN1B-10050 | NPN, two outputs (N1) | -100 to 1,000 kPa (10) | Rear cable (B), 5 m | $56.98 | |
| DPSP1-01020 | PNP, two outputs (P1) | -100 to 100 kPa (01) | Terminal connection, 2 m | $48.82 | |
| DPSP1-01030 | PNP, two outputs (P1) | -100 to 100 kPa (01) | Terminal connection, 3 m | $50.00 | |
| DPSP1-01050 | PNP, two outputs (P1) | -100 to 100 kPa (01) | Terminal connection, 5 m | $52.33 | |
| DPSP1B-01020 | PNP, two outputs (P1) | -100 to 100 kPa (01) | Rear cable (B), 2 m | $53.47 | |
| DPSP1B-01030 | PNP, two outputs (P1) | -100 to 100 kPa (01) | Rear cable (B), 3 m | $54.66 | |
| DPSP1B-01050 | PNP, two outputs (P1) | -100 to 100 kPa (01) | Rear cable (B), 5 m | $56.98 | |
| DPSP1-10020 | PNP, two outputs (P1) | -100 to 1,000 kPa (10) | Terminal connection, 2 m | $48.82 | |
| DPSP1-10030 | PNP, two outputs (P1) | -100 to 1,000 kPa (10) | Terminal connection, 3 m | $50.00 | |
| DPSP1-10050 | PNP, two outputs (P1) | -100 to 1,000 kPa (10) | Terminal connection, 5 m | $52.33 | |
| DPSP1B-10020 | PNP, two outputs (P1) | -100 to 1,000 kPa (10) | Rear cable (B), 2 m | $53.47 | |
| DPSP1B-10030 | PNP, two outputs (P1) | -100 to 1,000 kPa (10) | Rear cable (B), 3 m | $54.66 | |
| DPSP1B-10050 | PNP, two outputs (P1) | -100 to 1,000 kPa (10) | Rear cable (B), 5 m | $56.98 |
Need a combination that is not listed? Request a quote.
Signals the PLC when the line pressure drops below the set point.
The 01 range checks that a suction cup has picked the part.
Window mode switches only while the pressure is inside a set band.
Choose the output to match your PLC input: N1 gives two NPN outputs, P1 two PNP outputs.
Then the pressure range: 01 measures -100 to 100 kPa (vacuum and low pressure, proof 200 kPa), 10 measures -100 to 1,000 kPa (compressed air, proof 1,500 kPa).
Then the connection: no letter is the terminal connection, B the rear cable exit (IP63), D the bottom cable exit; the cable is 2, 3 or 5 m (020, 030, 050). The rear-exit version also comes with an M8 male connector on a 300 mm lead (M08), for the separate F-ECM08D cable.
Pick the one your controller input expects: N1 has two NPN outputs, P1 two PNP outputs. Each is rated 30 V, 100 mA, with less than 1.5 V residual voltage.
01 for vacuum and low pressure (-100 to 100 kPa), 10 for compressed air (-100 to 1,000 kPa).
Range 01: kPa, kgf/cm², bar, psi, mmHg, inHg. Range 10: MPa, kPa, kgf/cm², bar, psi, cmHg, inHg.
0 to 50 °C, 35 to 85% RH without condensation, 12-24 VDC ±10% with less than 10% ripple.
No. You can order a single piece. Orders are processed and handed to the carrier within 3-5 business days.
Every order code on this page is the AirTAC factory part number. Specifications follow the AirTAC Products Catalog 2026A. About us
That is our time to process the order and hand it to the carrier. No minimum order: a single piece can be ordered.
Return within 14 days of delivery; the buyer pays return shipping. The warranty covers defects not caused by misuse. Return policy
Send your application details and we will confirm the right order code, usually within 7-8 hours. Ask us
Page data checked against the live catalog on 2026-11-12.
Send the order code, quantity and destination. We confirm price, stock and lead time, usually within 7-8 hours.