The AirTAC B52-GFR Copper-Free Air Treatment Unit B52-GFR30015JC1WK is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$69.77 $75.19Save 7% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015JC1WK

The AirTAC GFR30015JC1WK is a G-series filter regulator with a built-in reverse (check) valve, supplied without a mounting bracket. It filters water and particulate, sets downstream pressure, and the check valve helps hold the downstream circuit if upstream supply is lost. This configuration carries a 1/2in PT port, a 5 um filtration element, a differential-pressure drain, and a round external gauge with MPa scale. Regulated range is 0.15-0.9 MPa (20-130 psi); maximum inlet pressure is 1.0 MPa (145 psi).

This is a genuine AirTAC part in the GFR300 size class; the G-series spans sizes 200, 300, 400 and 600, with bracket and no-bracket codes, check-valve fitment, drain types, filter grades and gauge options. Flow figures are published as curves rather than a single rating, so contact us and we will confirm the datasheet figures for your application on request.

Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015JC1WK Technical Specifications

ModelAirtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015JC1WK
SeriesGFR300 filter regulator
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015JC1WK

GFR300G-series filter regulator, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/2" · 5 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-15 (two-unit set)

Where the Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015JC1WK Is Used

settings_input_component

Robotic gripper panel conditioning

Filtered and regulated air on a robot gripper control panel, where the check valve keeps the gripper circuit from venting through the unit during momentary supply dips and the no-bracket code suits direct panel fixing.

science

Lab automation actuator supply

Conditioning the supply to pneumatic actuators on laboratory automation such as sample handlers and shuttle mechanisms, with the 5 um element protecting compact valve manifolds and the MPa gauge giving SI-unit setpoints.

tune

Textile machine jet and cylinder prep

Setting a clean, stable pressure for pneumatic thread-tension and lifting cylinders on textile machinery, where the reverse valve supports the loaded circuits and the 1/2in port matches the machine's main drop.

Is the Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015JC1WK the Right Unit?

GFR300 gives you a 1/2in PT port; step to 400 or 600 size where flow demand is higher. The K code fits the reverse/check valve for circuits that must resist backflow on supply loss - pick this over the plain unit for loaded or vertical actuators. The J code omits the mounting bracket, for direct plate or frame fixing; the non-J equivalent includes it. Drain is the differential-pressure type on this code; automatic and manual variants exist. The 5 um element (W) covers finer particle removal versus the 40 um standard grade. The round external gauge with MPa scale is fitted. PT thread is standard; G (BSPP) and NPT versions are available to order.

Because flow is published as curves and not a single rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015JC1WK FAQ

There is no single rated flow figure for this unit - AirTAC publishes flow as characteristic curves. We will not quote an estimated number; send us your supply pressure and the flow your application needs and we will confirm the sizing from the datasheet on request.

Two decode differences: J means the mounting bracket is omitted, and K means a reverse (check) valve is fitted so downstream pressure is not lost back through the unit on a supply failure. Filter grade (5 um), 1/2in PT port, differential-pressure drain and round MPa gauge are the same as the C1W version.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015JC1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for B52-GFR30015JC1WK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.