The AirTAC B52-GFR Copper-Free Air Treatment Unit B52-GFR30015LJC1W is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.
The GFR30015LJC1W is an AirTAC GFR300-series filter regulator in the low-pressure (L) type: a water-and-particulate filter and pressure regulator in one body, with no lubricator. This PT1/2 configuration has a fine 5 um element, a differential-pressure drain that clears the bowl automatically, an external round gauge (C) reading in MPa (scale 1), and no mounting bracket (J), suiting installations where the unit is supported by its own piping or an existing panel. The low-pressure type is meant for setpoints well below full line pressure; we confirm the exact adjustment range on request.
This is a genuine AirTAC part. Across the G series you can choose sizes 200 to 600, ports 1/8 inch to 1 inch, PT (standard), G or NPT threads, manual or automatic drains instead of the differential drain, 40 um or 5 um elements, and square embedded or round external gauges. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures for your application on request.
| Model | Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015LJC1W |
|---|---|
| Series | GFR300 filter regulator |
| Port size | PT1/2" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Low-pressure type |
| Adjusting mechanism | Balanced type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFR300 | G-series filter regulator, 300 body — sets the port range. |
|---|---|
| 15 | Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| L | Low-pressure type. Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.
| This model | GFR300 · PT1/2" · 5 µm |
|---|---|
| One size down | GFR200 |
| One size up | GFR400 |
| Add lubrication | GFC300-15 (two-unit set) |
Feeds filtered, low-pressure air to instrumented test benches and fixtures, where the visible MPa gauge supports repeatable test setup.
Regulates gentle air pressure for dancer arms and accumulator guides on wire and cable lines, protecting light mechanical linkages.
Supplies filtered air at a controlled low pressure to air-knife blow-off stations used to clean trailers, containers and returnable pallets.
Use the L type when the process setpoint sits well below full line pressure, and the C1 round MPa gauge when operators need to read and verify that setpoint directly. The J suffix omits the bracket; order the non-J variant if you need wall or panel fixing. The 5 um (W) element suits circuits with sensitive valves; the standard 40 um element is the economical choice for coarse protection. Drain type and PT versus G or NPT thread are also selectable. Since AirTAC publishes flow as curves and the low-pressure type carries its own band, ask us to confirm both sizing and the adjustment range against your application before ordering.
Quick checklist
The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. Without the K option, air cannot flow back through the unit. A filter regulator adds no oil to the line.
There is no single rated flow to quote; AirTAC publishes flow for this series as curves that depend on pressure and porting. Give us your pressure and demand figures and we will confirm the flow from the datasheet on request.
Only by the J: this code omits the mounting bracket, so the unit is supported by its piping or an existing panel. The low-pressure regulator type, PT1/2 port, 5 um element, differential-pressure drain and round MPa gauge are identical.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.