verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart1 Request a QuoteQuote
AirTAC GFR300 · Filter Regulator (filter + regulator in one body)

Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK

The AirTAC B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/2" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$46.16 $50.99Save 9% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK

The AirTAC GFR30015MJNWK is a combined filter regulator with a fitted reverse (check) valve: it filters water and particulate from compressed air, holds a stable downstream pressure, and the K option prevents backflow through the unit. This 300-size build has a 1/2 in PT port, a manual drain on the PC bowl, a fine 5 um element, and no gauge (N). Medium is compressed air only, maximum working pressure is 1.0 MPa (145 psi), and the manual-drain regulation range is 0.05-0.9 MPa (7-130 psi). Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part from the G series filter regulator family, which spans sizes 200 to 600 with ports from 1/8 in to 1 in, optional G (BSPP) or NPT threads, and gauge or no-gauge configurations in the catalogue. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.

Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK Technical Specifications

ModelAirtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK
SeriesGFR300 filter regulator
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK

GFR300G-series filter regulator, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
JSupplied without bracket.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR300 · PT1/2" · 5 µm
One size downGFR200
One size upGFR400
Add lubricationGFC300-15 (two-unit set)

Where the Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK Is Used

shield

Downstream pressure hold on clamp circuits

Filters and regulates supply air to a safety-relevant clamping circuit while the reverse valve helps keep downstream pressure from bleeding back through the prep unit on supply loss.

local_shipping

Trailer tipper and dock equipment air

Prepares filtered, regulated air for the cylinders on dock levellers and trailer tippers, with manual drain points serviced during scheduled yard maintenance and the check valve guarding the regulated branch.

engineering

Field-rigged pneumatic test stand

Used on a mobile or bench-mounted pneumatic test rig where clean 5 um-filtered air at a controlled pressure feeds the device under test, with the reverse valve isolating the rig from backflow.

Is the Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK the Right Unit?

Pick the 300 size with 1/2 in PT port for mid-to-large supply lines, stepping down to 200 or up to 400/600 as demand dictates. The manual drain suits installations with routine inspection rounds; automatic or differential-pressure drain is available otherwise. The 5 um (W) element filters finer than the 40 um standard. The K suffix adds the reverse (check) valve for circuits where backflow must be blocked; drop the K for a plain unit. The N suffix deletes the gauge - embedded square gauge and external round gauge builds in MPa, psi or bar scale are alternatives - and J means no mounting bracket. PT is the standard thread, with G and NPT orderable.

Since flow is published as curves rather than a single rated figure, share your line demand and we will confirm the datasheet figures and sizing before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK FAQ

AirTAC publishes flow for the GFR300 series as curves rather than one rated number, so we do not quote a single figure. Send us your operating pressure and air consumption and we will confirm the datasheet curve and verify this 1/2 in size for your application on request.

The trailing K means a reverse (check) valve is fitted, so downstream air cannot push back through the filter regulator. Drain type, filter grade, gauge and thread stay the same as the plain build - this unit is manual drain, 5 um element, no gauge, 1/2 in PT port. Order the code without K if backflow protection is not needed.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR30015MJNWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for B52-GFR30015MJNWK and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.