The AirTAC GAC F.R.L. Unit GAC30010ALNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this GAC30010ALNT assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port pairs with a 40 um element, while the automatic drain empties the 60 cc condensate bowl without operator intervention. Because the lower-pressure type caps the operating range at 0.15-0.4 MPa (20-58 psi), it targets low-force actuator circuits rather than general plant air.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat stays clean. Weighing 1300 g, this body size is substantial enough to require a panel or frame mount rather than tubing support. No gauge is supplied, but a 1/8in gauge connection allows operators to add instrumentation for verifying the set pressure. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30010ALNT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds small robotic grippers and delicate pick-and-place actuators operating safely within the 0.15-0.4 MPa band.
Conditions air for sensitive laboratory fluid dispensing where a 40 um filter captures particulates without restricting flow.
Regulates low-tension pneumatic dancers and fabric guide cylinders that would be overpowered by standard 0.9 MPa supply.
Choose this 3/8in PC bowl unit when a machine demands the 0.15-0.4 MPa (20-58 psi) lower-pressure range and automatic condensate removal. The 40 um element suits general pneumatic protection, whereas stepping up to a GAC400 body provides a larger 100 cc drain bowl for wetter environments. Since no gauge is included, the 1/8in port must be fitted with a separate pressure indicator. If the downstream line must remain oil-free, omit the lubricator and choose a filter-regulator instead. Spares follow the body and port exactly: GAF300-10, GAR300-10 and GAL300-10. The 0.4 MPa ceiling is 44% of the standard 0.9 MPa maximum, so verify your actuators never require more force than this lower limit allows.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, features a 60 cc drain bowl and a 98 cc oil bowl, uses ISO VG 32 lubricant, and weighs 1300 g.
The N in the ordering code signifies no gauge is supplied. The body features a 1/8in gauge connection, allowing you to install a separate NPT-threaded gauge reading in MPa/psi to monitor the 0.15-0.4 MPa output.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.