The AirTAC GAC F.R.L. Unit GAC30010ASNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC F.R.L. combination pre-assembles a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. It is built for a 3/8in port, carries a 5 um element for fine particle capture, and operates within the 0.15-0.9 MPa (20-130 psi) standard pressure range. Weighing 1300 g, the assembly routes air sequentially so the oil mist is added downstream of the regulator, preventing oil from fouling the regulating seat.
Because the code carries an N after the port, no pressure gauge is supplied; operators can add one via the 1/8in gauge connection. The unit features an automatic drain that clears condensate from the 60 cc bowl without manual intervention, while the 98 cc oil reservoir sets the lubrication refill interval. Ambient conditions must stay between -5 to 70 C without freezing, and the assembly accepts GAF300-10, GAR300-10 and GAL300-10 spares. Order code GAC30010ASNWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30010ASNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive directional control valves on a machining center where the 5 um element protects internal spools from fine particulate damage.
Conditions air for high-speed packaging actuators, utilizing the automatic drain to handle moisture generated during continuous duty cycles.
Supplies clean, lubricated air to benchtop analytical equipment, requiring the 3/8in port and stable 0.15-0.9 MPa output for delicate procedures.
Choose this PC bowl model for unattended or wet lines where the automatic drain prevents condensate build-up, and specify it when your downstream precision valves require the 5 um element instead of the standard 40 um grade. The missing gauge keeps the unit compact, but you cannot read the set pressure without fitting one to the 1/8in port. If your machine requires completely oil-free output downstream, omit the lubricator and select a dedicated filter-regulator instead. The catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, which is half of the GAC400's 6000 L/min envelope, allowing clear sizing between bodies. Since the maximum supply is 1.0 MPa and the standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates between 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, features a 60 cc drain bowl, a 98 cc oil bowl, weighs 1300 g, and uses ISO VG 32 lubricant.
The N in the ordering code signifies that no circular gauge is supplied, meaning the set pressure cannot be read directly unless you add one to the 1/8in gauge connection. This configuration is often chosen to reduce height in tight panels or when pressure is monitored downstream.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.