The AirTAC GAC F.R.L. Unit GAC30010ASWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC30010ASWTK is a three-unit F.R.L. combination pre-plumbed on a single L-shape bracket. It features a 3/8in port, a 5 um element for trapping finer particles, and operates within the 0.15-0.9 MPa (20-130 psi) standard pressure range. A circular gauge reading MPa/psi is fitted to display the set pressure, and the assembly includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol.
The internal build order routes air through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. With a 60 cc condensate bowl and a 98 cc oil reservoir, this 1300 g unit balances a compact footprint against a manageable service interval. The automatic drain clears accumulated water without an operator, making it well suited to unattended or wet lines, and the temperature floor of -5 to 70 C means it must not freeze. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30010ASWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Supplies finely filtered, lubricated air to pneumatic tool changers and actuated clamps on CNC machining centres.
Conditions air for continuous-motion packaging equipment where the auto drain handles condensate during unattended shifts.
Feeds precision pneumatic gauges and small actuators in testing laboratories using the 5 um filtration grade.
Choose this GAC300 model for mid-size duties where the 3/8in port and 5 um element suit precision valves or instrument air, trading off against more frequent element service than the standard 40 um grade. The PC bowl handles the 1.0 MPa (145 psi) maximum pressure, while the fitted NPT thread gauge reads in MPa/psi. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. The three constituent units are separately orderable as GAF300-10, GAR300-10 and GAL300-10, so a clogged element or damaged bowl does not require replacing the whole assembly. The catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, which is exactly double the 1750 L/min envelope of the smaller GAC200, giving a clear path to size up or down. Because the maximum supply is 1.0 MPa and the standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, uses a 60 cc drain bowl and a 98 cc oil bowl, weighs 1300 g, and requires ISO VG 32 or equivalent lubricant.
The K indicates that a reverse-flow (reflux) valve is fitted to this unit. The catalogue displays this as a separate pneumatic symbol with details on its own page, representing an ordering difference rather than a standard feature.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.