The AirTAC GAC F.R.L. Unit GAC30010LNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port serves the GAC300 size class, which carries a 60 cc condensate bowl and a 98 cc oil reservoir. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling during pressure control.
Configured for low-pressure duties, the assembly regulates between 0.15-0.4 MPa (20-58 psi) and uses a 40 um element. No gauge is supplied, but the body features a 1/8in gauge connection if visual monitoring is added later. The semi-auto and manual drain pair clears accumulated moisture, with a total mass of 1300 g requiring a firm panel or frame mount rather than tubing support. Order code GAC30010LNT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30010LNT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeding delicate pneumatic grippers handling electronics where actuation forces must stay below 0.4 MPa to avoid crushing components.
Supplying regulated, lubricated air to small packaging bag formers and seal jaws that rely on consistent low-pressure cylinders.
Conditioning air for benchtop fluid dispensing robots and analytical instruments needing stable, low-energy pneumatic inputs.
Choose this low-pressure variant when a machine circuit operates strictly within a 0.15-0.4 MPa (20-58 psi) window, as the internal spring is optimized for that narrow band rather than the standard 0.9 MPa ceiling. The standard 40 um filter captures general pipe scale, while the PC bowl suits typical industrial environments. If your line must remain completely oil-free, omit the lubricator and select a dedicated filter-regulator instead. Should a component wear out, the assembly breaks down into separately orderable spares: GAF300-10, GAR300-10 and GAL300-10. Stepping down to the GAC200 body reduces the plotted flow envelope from 3000 L/min to 1750 L/min at 0.7 MPa inlet, whereas stepping up to the GAC400 doubles it to 6000 L/min. Keep in mind that the 0.4 MPa upper limit is 44% of the standard 0.9 MPa ceiling, so verify your actuators never require more force than this lower range permits.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure F.R.L. combination regulates from 0.15-0.4 MPa (20-58 psi) and has a maximum pressure of 1.0 MPa (145 psi) with a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, features a 60 cc drain bowl and a 98 cc oil bowl, and uses ISO VG 32 lubricant.
The N in the product code indicates no gauge is supplied. The unit has a 1/8in gauge connection on the body, allowing operators to install a separate gauge reading in MPa or psi if visual pressure verification is needed at the 3/8in port.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.