The AirTAC GAC F.R.L. Unit GAC30010LNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, lubricated air at a strictly capped downstream pressure, this AirTAC assembly integrates a filter, regulator and lubricator on a shared L-shape bracket. The 3/8in port serves mid-volume duties, while the lower-pressure type confines output to 0.15-0.4 MPa (20-58 psi). A 5 um element captures fine particulates before they reach sensitive valves.
Because no gauge is supplied, operators must add one to the 1/8in gauge connection to verify the setpoint. The 60 cc condensate sump and 98 cc oil reservoir dictate the maintenance rhythm, and the semi-auto plus manual drain pair clears water on every pressure drop or on demand. Order code GAC30010LNWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30010LNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate pneumatic stirrers and low-pressure sprayers in research labs, ensuring the 5 um element prevents clogging of fine nozzles.
Supplies a steady, low-force air supply to sensitive yarn-guiding actuators, protecting fragile fabrics from over-tensioning.
Conditions air for small-bore clamping cylinders on electronics assembly fixtures, adding necessary oil mist for smooth actuator cycling.
Choose this configuration for instrument-air circuits or low-force actuators where exceeding 0.4 MPa would cause damage, noting that stepping up to the GAC400 body doubles the plotted flow envelope to 6000 L/min at 0.7 MPa inlet for higher consumption. If the machinery requires completely dry, oil-free exhaust, substitute a dedicated filter-regulator instead of this lubricated setup. The 5 um mesh protects precision components but requires more frequent replacement than the 40 um standard, and individual service parts carry the GAF300-10, GAR300-10 and GAL300-10 designations. By choosing the L type, the operator accepts a ceiling that is 44% of the standard 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi), with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, and pairs a 60 cc drain bowl with a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The N in the code means no gauge is fitted, so you must install one in the 1/8in connection to read the downstream setting. The W denotes a 5 um element, which traps much finer particles than the 40 um standard to protect precision valves, though it will require more frequent cleaning.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.