The AirTAC GAC F.R.L. Unit GAC30010SNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-range pneumatics, this AirTAC GAC30010SNTK pre-assembles a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/8in port pairs with a standard 0.15-0.9 MPa (20-130 psi) operating range and a 40 um element. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling during pressure modulation.
This configuration carries a PC bowl and omits the pressure gauge, leaving a 1/8in gauge connection for operators to add instrumentation if needed. The 60 cc condensate bowl and 98 cc oil sump dictate the maintenance interval, while the reverse-flow (reflux) valve is fitted, appearing as a separate pneumatic symbol in the catalogue. Replacement internals follow the body-port suffix, taking GAF300-10, GAR300-10 and GAL300-10 units. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30010SNTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeding a row of pneumatic grippers and clamps on an automated assembly station where a steady 3/8in air supply and added oil mist protect moving seals.
Conditioning drive air for the folding cylinders and vacuum generators on a continuous-motion packaging machine, relying on the 40 um element to prevent valve blockages.
Supplying regulated, lubricated air to pneumatic pop-up sorters and diverters along a parcel handling conveyor to maximize cylinder lifespan.
Choose this 1300 g assembly when a mid-size body is required without factory-fitted pressure monitoring, relying instead on the 1/8in port to add a gauge. The PC bowl suits general industrial environments, and the semi-auto plus manual drain pair gives operators dual control over condensate evacuation. If the downstream line must remain completely oil-free, this lubricator should be omitted in favour of a dedicated filter-regulator. The 40 um element is standard, catching bulk water and particulates before they reach downstream valves.
The catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, offering exactly double the sizing envelope of the 1750 L/min GAC200. When sizing for maximum outlet pressure, remember that the 1.0 MPa supply ceiling leaves only about 0.1 MPa of headroom above the 0.9 MPa standard setting.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in -5 to 70 C temperatures, weighs 1300 g, and features a 60 cc drain bowl alongside a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
No gauge is supplied; instead, it provides a 1/8in connection for adding one later. The NPT thread dictates an MPa/psi scale if a gauge is installed. Additionally, this model has the reverse-flow (reflux) valve fitted, which the catalogue details on its own page.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.