The AirTAC GAC F.R.L. Unit GAC30010SWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC unit integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. It features a 3/8in port, a standard pressure range of 0.15-0.9 MPa (20-130 psi), and a 5 um element that traps far finer particles than the default 40 um grade, making it ideal for protecting precision valves. A circular gauge reading MPa/psi is fitted for the default NPT thread.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. The 1300 g assembly carries a 60 cc condensate bowl and a 98 cc oil reservoir. It ships with both a semi-auto drain, which dumps condensate on every pressure drop, and a manual drain for on-demand emptying. If your downstream line requires strictly oil-free air, you must omit the lubricator and select a dedicated filter-regulator instead. Order code GAC30010SWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC30010SWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air to precision tool changer cylinders, where the 5 um element prevents grit from jamming internal mechanisms.
Conditions air for high-speed packaging actuators, with the 60 cc drain bowl catching condensate during extended production runs.
Supplies a steady 0.15-0.9 MPa pressure to pneumatic rapier mechanisms, adding necessary oil mist to reduce wear on moving guides.
Choose this GAC300 body for mid-range duties where the 3/8in port matches your flow requirements, stepping up to the GAC400 if you need a larger 100 cc condensate bowl. The PC bowl on this model handles standard 1.0 MPa (145 psi) max pressures and -5 to 70 C temperatures, though you should confirm material compatibility for aggressive chemical surroundings. The 5 um W element provides superior filtration over the standard 40 um option, though it will require more frequent service. Should a component fail, order spares using the same body-port suffix: GAF300-10, GAR300-10 and GAL300-10. Stepping down from the GAC400, the plotted flow envelope of 3000 L/min at 0.7 MPa inlet is exactly half the size, giving you a clear 2x ratio for sizing down your supply.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It functions from -5 to 70 C, weighs 1300 g, and uses a 60 cc drain bowl alongside a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The W code specifies a 5 um element, which catches significantly finer particles than the standard 40 um filter to protect sensitive instruments. The blank drain position means both a semi-auto drain, which expels water automatically during pressure drops, and a manual drain are fitted to the PC bowl.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.