The AirTAC GAC F.R.L. Unit GAC30010SWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this GAC30010SWTK assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port pairs with a 5 um element to trap fine particles before they reach precision valves. This order code has NPT ports (the T in the code); the PT and G versions are separate order codes. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling during pressure modulation.
Weighing 1300 g, this body size requires a secure panel or frame mount rather than tubing support. The 60 cc condensate bowl and 98 cc oil reservoir dictate the maintenance rhythm, and operators can monitor settings via the installed gauge. A reverse-flow (reflux) valve is fitted, appearing as a distinct pneumatic symbol in the catalogue. The unit operates between -5 to 70 C, and individual service parts are available as GAF300-10, GAR300-10 and GAL300-10.
| Model | Airtac GAC F.R.L. Unit GAC30010SWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air at a stable pressure to pneumatic tool change cylinders, protecting tight clearances from fine particulates.
Conditions supply air for high-cycle heat-sealing actuators, ensuring consistent motion and preventing stiction on moving parts.
Regulates and lubricates air for spinning machine cylinders, where the 5 um element guards delicate air-jet nozzles from clogging.
Choose this 3/8in configuration when a system demands the 5 um particle protection of the W element over the standard 40 um grade, accepting that finer filtration requires more frequent element changes. The PC bowl is paired with a semi-auto and manual drain, discharging condensate on pressure drops or on demand. If a machine requires completely oil-free output downstream, omit the lubricator stage and select a filter-regulator instead. The fitted gauge reads in MPa/psi for the default NPT thread, and the reverse-flow valve is included as an ordering distinction. Stepping up to the GAC400 body increases the plotted flow envelope from 3000 L/min to 6000 L/min at 0.7 MPa inlet, doubling the available air capacity. The 1.5 MPa proof pressure provides a 1.5x burst-test margin above the 1.0 MPa maximum operating limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) and has a maximum pressure of 1.0 MPa (145 psi) with a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, uses a 5 um element, and weighs 1300 g. The condensate bowl holds 60 cc and the oil bowl holds 98 cc, requiring ISO VG 32 lubricant.
The K indicates that a reverse-flow (reflux) valve is attached to the unit. The catalogue lists this component as a separate pneumatic symbol on its own page, and its specific operational function should be confirmed from that datasheet.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.