The AirTAC GAC F.R.L. Unit GAC300C10ALNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC GAC300C10ALNTK combines a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port serves mid-scale duties, while the 40 um element captures solid grain before the 0.15-0.4 MPa (20-58 psi) lower-pressure range is set. An automatic drain clears condensate from the 60 cc metal bowl without an operator.
Because the lubricator sits last in the sequence, oil mist is added downstream of the regulator seat, preventing fouling. This specific assembly carries a reverse-flow (reflux) valve, which the catalogue depicts as a separate pneumatic symbol with details on its own page. No gauge is supplied, but a 1/8in connection is ready if you need to add one to read the set pressure. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C10ALNTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds cushioning cylinders on a flow-wrap machine that require a gentle 0.4 MPa maximum operating pressure to prevent film tearing.
Conditions supply for delicate pneumatic dispensers where the 3/8in port and lower-pressure ceiling protect sensitive glass or plastic components.
Regulates air for low-tension fabric guiding actuators, adding a controlled oil mist downstream to keep moving parts lubricated.
Choose this metal-bowl unit for environments where PC or nylon might not suit the surroundings, keeping in mind the 1.0 MPa (145 psi) maximum and -5 to 70 C limits are identical across all materials. The automatic drain suits unattended or wet lines, and the 40 um element balances protection with service frequency. If the machine must stay oil-free, omit the lubricator and choose a filter-regulator instead. For maintenance, the three units are separately orderable as GAF300-10, GAR300-10 and GAL300-10, so a clogged element does not require replacing the whole assembly. Stepping up to the GAC400 roughly doubles the plotted flow envelope to 6000 L/min at 0.7 MPa inlet compared to this body's 3000 L/min, but stepping down to the GAC200 halves the 60 cc condensate capacity to 25 cc. Finally, the lower-pressure type tops out at 0.4 MPa, which is 44% of the Standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type regulates from 0.15-0.4 MPa (20-58 psi). It shares the common 1.0 MPa (145 psi) maximum pressure and 1.5 MPa (215 psi) proof pressure. Operating temperature is -5 to 70 C. The metal unit weighs 1300 g, holds 60 cc of condensate and 98 cc of oil, and uses ISO VG 32 lubricant.
The N in the code means no gauge is supplied, leaving a 1/8in connection for you to add one if reading the set pressure is necessary. The K denotes a reverse-flow (reflux) valve fitted to the unit, shown as a separate pneumatic symbol in the catalogue.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.