The AirTAC GAC F.R.L. Unit GAC300C10ALNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The metal bowl variant is paired with a 3/8in port, while the 5 um element captures fine particles for sensitive downstream valves. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling.
This specific configuration regulates pressure within a lower 0.15-0.4 MPa (20-58 psi) range, making it unsuitable for machines that may ever require higher actuation force. The automatic drain clears condensate from the 60 cc bowl without operator intervention, ideal for unattended or wet lines. A reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue, and no gauge is supplied out of the box. Order code GAC300C10ALNWTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C10ALNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive solenoid valve banks requiring 5 um filtered, oil-misted air at low actuation pressures.
Conditions supply air for delicate test fixtures where the 0.15-0.4 MPa lower-pressure range prevents damage to sensitive components.
Prepares air for small pick-and-place actuators, with the automatic drain handling condensate during continuous unattended shifts.
Choose this 1300 g assembly for mid-scale duties where the plotted catalogue flow curve extends to 3000 L/min at 0.7 MPa inlet, roughly double the envelope of the smaller GAC200. The metal bowl offers robustness for industrial environments, while the 5 um element suits precision instrument air at the cost of more frequent service. If the downstream line must remain strictly oil-free, omit the lubricator and choose a separate filter-regulator instead. Spares share the same body-port suffix: GAF300-10, GAR300-10 and GAL300-10.
Because the lower-pressure type tops out at 0.4 MPa, it operates at about 44% of the Standard type's 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure type regulates from 0.15-0.4 MPa (20-58 psi). It has a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C. The drain bowl holds 60 cc and the oil bowl holds 98 cc, with a total weight of 1300 g. Use ISO VG 32 or equivalent lubricant.
The N in the model code indicates no gauge is supplied. The body features a 1/8in gauge connection, allowing you to install a separate gauge reading MPa/psi for the default NPT thread if you need to monitor the set pressure.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.