The AirTAC GAC F.R.L. Unit GAC300C10ASNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, pressure-set and oil-misted air, this AirTAC GAC300C10ASNWT combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/8in port serves a 1300 g assembly that uses a 5 um element to trap fine particles for precision pneumatics. Because the lubricator sits last in the sequence, oil mist enters downstream of the regulator seat, preventing fouling. A metal bowl houses the 60 cc condensate sump and 98 cc oil reservoir.
This variant carries an automatic drain, clearing water without an operator on every pressure drop, which suits unattended or wet lines. No gauge is supplied, but the body features a 1/8in gauge connection for adding one later. Operating pressure spans 0.15-0.9 MPa (20-130 psi), and the unit accepts AirTAC GAF300-10, GAR300-10 and GAL300-10 spares. The catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C10ASNWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds sensitive pneumatic tool changers requiring finely cleaned 5 um air to prevent stiction in precision valves.
Conditions air for high-speed packaging machinery where the automatic drain handles condensate during continuous unattended shifts.
Lubricates and regulates air for multi-actuator spinning frames, using the metal bowl to withstand industrial ambient conditions.
Choose this metal-bowl unit for harsher environments where standard PC might not suit, bearing in mind the common 1.0 MPa max and -5 to 70 C limits apply to all materials. The 5 um W element catches far finer dust than the 40 um standard, trading off more frequent service for better protection of sensitive valves. Since no gauge is included, the set pressure cannot be read without adding one to the 1/8in port. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. Stepping up to the GAC400 moves the plotted flow envelope to 6000 L/min at 0.7 MPa inlet, double the GAC300's 3000 L/min capacity. Max supply is 1.0 MPa and the Standard type regulates to 0.9 MPa, leaving only about 0.1 MPa of headroom, so plan a supply near 1.0 MPa if you truly need 0.9 MPa out.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, and pairs a 60 cc drain bowl with a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The N in the code means no gauge is supplied, so you cannot read the set pressure unless you add your own to the 1/8in gauge connection. This setup lets you install a custom dial or remote sensor tailored to your specific equipment.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.