The AirTAC GAC F.R.L. Unit GAC300C10LNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this GAC300C10LNT assembly integrates a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/8in port pairs with a 1300 g body mass, placing it firmly in the mid-size class for machine panel mounting rather than tubing support. Air passes through the 40 um filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls.
Configured for low-pressure duties, this unit regulates between 0.15-0.4 MPa (20-58 psi) and carries a metal bowl. No gauge is supplied, but the body features a 1/8in gauge connection if you need to add instrumentation later. The condensate bowl holds 60 cc and the oil reservoir 98 cc, establishing the maintenance interval, while the semi-auto and manual drain pairing clears water on every pressure drop or on demand. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C10LNT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate pneumatic grippers on small assembly jigs where pressure must stay below 0.4 MPa to avoid crushing fragile components.
Conditions air for heat-sealing actuators in packaging lines, adding the required oil mist for continuous moving parts.
Prepares supply air for sensitive lab distribution panels, using the metal bowl to withstand regular cleaning protocols.
Choose this specific configuration when your actuators require a maximum of 0.4 MPa, as the lower-pressure type tops out well below the standard 0.9 MPa ceiling. The metal bowl suits harsher industrial environments where polycarbonate might be at risk, though buyers must confirm chemical compatibility for aggressive solvents. Since no gauge is included, the set pressure cannot be read without adding one to the 1/8in connection. If your process demands completely oil-free downstream air, omit the lubricator and select a filter-regulator instead. For maintenance, the assembly accepts individual GAF300-10, GAR300-10 and GAL300-10 replacement units. Stepping up to the GAC400 body increases the condensate bowl from 60 cc to 100 cc, but choosing the L type here means your pressure ceiling is 44% of the standard 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates in temperatures from -5 to 70 C, weighs 1300 g, features a 60 cc drain bowl and a 98 cc oil bowl, and uses ISO VG 32 lubricant.
The N in the ordering code indicates no gauge is supplied, meaning you cannot read the set pressure without adding your own instrumentation to the 1/8in gauge connection. This allows operators to fit a specific gauge scale or remote pressure sensor tailored to the low-pressure 0.15-0.4 MPa range.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.