The AirTAC GAC F.R.L. Unit GAC300C10SNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC300C10SNWTK combines a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port pairs with a standard pressure range of 0.15-0.9 MPa (20-130 psi) and a 5 um element to trap fine particles before they reach sensitive valves. Its 1300 g mass and metal bowl suit demanding industrial frames rather than lightweight tubing supports.
Air flows through the filter first, then the regulator, with oil mist added last so the internal seat never fouls. Because no gauge is supplied, operators must use the 1/8in gauge connection to add instrumentation if they need to read the set pressure. The reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300C10SNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Supplies finely filtered, oil-misted air to precision pneumatic tool changers on CNC machining centres.
Conditions air for high-speed packaging cylinders, ensuring consistent actuator speed and preventing valve stiction.
Prepares supply air for loom and spinner actuators, protecting moving parts from grit and moisture in humid mill environments.
This unit uses a metal bowl and a 5 um element, offering finer filtration than the 40 um standard at the cost of more frequent element service. The semi-auto and manual drain pair handles condensate on demand, while the missing gauge means you rely on external instrumentation to verify the 0.15-0.9 MPa (20-130 psi) outlet. If the downstream line must stay completely oil-free, omit the lubricator and choose a filter-regulator instead. Replacement spares share the same 3/8in port suffix: GAF300-10, GAR300-10 and GAL300-10. Stepping up to the GAC400 body roughly doubles the plotted flow envelope from 3000 to 6000 L/min at 0.7 MPa inlet, but the GAC300 holds a 2x condensate capacity advantage over the 25 cc GAC200.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It features a 3/8in port, a 5 um element, a 60 cc drain bowl, a 98 cc oil bowl, and weighs 1300 g. The operating temperature is -5 to 70 C, and the recommended lubricant is ISO VG 32.
The N in the ordering code indicates no gauge is supplied. The block has a 1/8in gauge connection, allowing you to install a separate instrument reading MPa/psi to match the default NPT thread. You must add a gauge to read the downstream set pressure during adjustment.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.