The AirTAC GAC F.R.L. Unit GAC300N10ALNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAC300N10ALNTK is a three-unit F.R.L. combination - a filter, a regulator and a lubricator - pre-assembled on a single L-shape bracket with quick mounting clamps, so there is no inter-unit tubing to leak. Air passes through the filter, then the regulator, and the oil mist is added last, downstream of the regulator seat, which keeps the oil from fouling the regulation mechanism.
The 3/8in port and 1300 g mass place it in the GAC300 size class, a step up from the GAC200's 750 g frame. Its nylon bowls hold 60 cc of condensate and 98 cc of oil, and the lower-pressure regulator tops out at 0.4 MPa (20-58 psi). The 40 um element handles standard shop air, and the automatic drain clears water without an operator. No gauge is supplied; the 1/8in gauge connection is there if you add one later. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N10ALNTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feed a 3/8in line to a bench-mounted clamping jig that needs a gentle, repeatable 0.3 MPa grip on delicate parts, with the automatic drain handling condensate from a humid shop line.
Supply a laboratory test bench where instruments require a stable low pressure around 0.35 MPa, and the nylon bowl resists incidental solvent splashes better than PC in a fume-prone area.
Run a small assembly station's single-acting actuators and air blow-off nozzles at a capped 0.4 MPa, keeping the force low for hand-guided operations and letting the auto drain run unattended.
Choose the GAC300N10ALNTK when your line needs a 3/8in port and a lower-pressure ceiling of 0.4 MPa (20-58 psi) - if the machine may ever need more than that, the L type is the wrong part, so step up to the standard S type instead. The nylon bowl is a build choice for the environment, but the common specification (1.0 MPa max, -5 to 70 C) is the same as PC or metal, so confirm compatibility for aggressive surroundings. The automatic drain suits unattended or wet lines, and the reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page. The 40 um element is the standard grade; the 5 um W option is available if you need finer filtration. Spares for this body-port are GAF300-10, GAR300-10 and GAL300-10, all sharing the same suffix. This L-type ceiling is about 44% of the standard type's 0.9 MPa maximum, so you give up over half the regulation range by choosing it.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
The GAC300N10ALNTK is a lower-pressure F.R.L. combination operating at 0.15-0.4 MPa (20-58 psi), with a maximum supply pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It is rated for -5 to 70 C and must not freeze. The drain bowl holds 60 cc and the oil bowl 98 cc. Recommended lubricant is ISO VG 32, and the unit weighs 1300 g.
The N after the port code means no gauge is supplied with this unit. The set pressure cannot be read without adding one. The gauge connection on the GAC300 body is 1/8in, so you can fit a compatible gauge there if you need to monitor the outlet pressure.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.