The AirTAC GAC F.R.L. Unit GAC300N10ASNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this GAC300N10ASNTK combines a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port serves the 0.15-0.9 MPa (20-130 psi) standard pressure range, while the 40 um element captures solid grain before it reaches valves. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling of the internal pressure control mechanism.
This specific configuration uses a nylon bowl and ships without a pressure gauge, leaving the 1/8in gauge connection free for a user-supplied instrument. An automatic drain actively expels condensate from the 60 cc bowl without operator intervention, which is decisive for unattended machinery. A reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue, and the entire 1300 g assembly mounts via quick clamps. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N10ASNTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multiple pneumatic grippers and actuators on a rotary indexing table where the automatic drain handles condensate during continuous three-shift operation.
Conditions air for vacuum generators and sealing cylinders, relying on the 40 um element to prevent dust ingestion in high-throughput packaging facilities.
Supplies a steady 0.15-0.9 MPa output to air-jet looms, with the nylon bowl offering impact resistance in environments where thread breakage and mechanical debris are common.
When sizing this unit, the GAC300 body offers a flow envelope plotted to 3000 L/min at 0.7 MPa inlet, sitting between the lighter GAC200 (1750 L/min) and the heavier GAC400 (6000 L/min). The nylon bowl material provides a robust alternative to the standard PC or metal options, though buyers must confirm chemical compatibility for aggressive environments. If your line requires completely oil-free output, omit the lubricator and choose a dedicated filter-regulator instead. Replacement spares follow the body and port exactly: GAF300-10, GAR300-10 and GAL300-10. Keep in mind that the 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin above the 1.0 MPa maximum, which is a safety rating rather than permission to operate above the stated ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, and features a 60 cc drain bowl alongside a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
The N in the ordering code indicates no gauge is supplied. The body features a 1/8in gauge connection, allowing operators to install a specific pressure reading instrument that matches their local requirements. The set pressure cannot be visually verified without adding this external component.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.