The AirTAC GAC F.R.L. Unit GAC300N10ASNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in ported GAC300 body carries a 5 um element for trapping finer particulates than the standard 40 um grade, making it better suited for sensitive instrumentation. It regulates across 0.15-0.9 MPa (20-130 psi) and features a nylon bowl.
Because no pressure gauge is supplied, operators must add one to the 1/8in gauge connection to read the setpoint. The automatic drain empties the 60 cc condensate bowl without manual intervention, while the 98 cc oil reservoir feeds a controlled mist downstream of the regulator seat. This specific configuration also includes a reverse-flow (reflux) valve, which the catalogue depicts as a separate pneumatic symbol. Order code GAC300N10ASNWTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N10ASNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Supplies finely filtered, lubricated air to pneumatic tool changer cylinders on machining centers, protecting close-tolerance moving parts from abrasive grit.
Conditions instrument air for sensitive pneumatic actuators in laboratory automation, where the 5 um element prevents particulate fouling of small internal orifices.
Feeds continuous-motion packaging machinery where the automatic drain handles condensate during wet production shifts without halting the line.
Choose this 1300 g unit when a machine requires precision filtration and unattended condensate management. The 5 um element catches fine grit that would abrade close-tolerance valves, though it requires more frequent replacement than the 40 um default. The nylon bowl suits standard -5 to 70 C environments, but chemical compatibility should be verified for aggressive solvents. If the downstream line must remain completely oil-free, omit the lubricator and select a standalone filter-regulator instead. Replacement spares share the same body-port suffix: GAF300-10, GAR300-10 and GAL300-10.
Sizing the air supply requires care, as the catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, which is 50% of the GAC400's 6000 L/min envelope. Furthermore, with a maximum supply of 1.0 MPa and a standard regulating ceiling of 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 1300 g, and uses a 60 cc drain bowl alongside a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
Because the N appears after the 3/8in port code, it indicates that no pressure gauge is supplied. To monitor the downstream setting, a circular gauge must be fitted to the 1/8in gauge connection. The N before the port denotes the nylon bowl material.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.