The AirTAC GAC F.R.L. Unit GAC300N10LNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 3/8in port, a 5 um element and a nylon bowl. The lower pressure type restricts the operating range to 0.15-0.4 MPa (20-58 psi), suiting sensitive actuators. A reverse-flow valve is fitted, shown as a separate pneumatic symbol in the catalogue.
Because no gauge is supplied, operators must use the 1/8in gauge connection to add one if they need to read the set pressure. The 60 cc condensate bowl and 98 cc oil sump dictate the maintenance frequency. Air passes through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Order code GAC300N10LNWTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N10LNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure instrument air to sensitive directional valves, relying on the 5 um element to prevent spool sticking.
Regulates air for delicate test fixtures requiring a strict 0.15-0.4 MPa (20-58 psi) range to avoid damaging glass or plastic components.
Conditions air for low-force carton erecting cylinders where the nylon bowl withstands typical ambient shop conditions.
Choose this 1300 g assembly when an application demands low-pressure regulation between 0.15-0.4 MPa (20-58 psi) and fine 5 um filtration. The nylon bowl offers a specific build choice for certain environments, while the semi-auto and manual drain pair handles condensate. If the machine requires oil-free downstream air, omit the lubricator and select a filter-regulator instead. The three units are separately orderable as GAF300-10, GAR300-10 and GAL300-10. Keep in mind the lower-pressure ceiling is 44% of the Standard type's 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 60 cc drain bowl, a 98 cc oil bowl, a 5 um element, and weighs 1300 g. The recommended lubricant is ISO VG 32.
The N in the model code indicates no gauge is supplied. The unit has a 1/8in gauge connection, allowing you to install a separate gauge reading MPa/psi for the default NPT thread if you need to monitor the 0.15-0.4 MPa set pressure.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.