The AirTAC GAC F.R.L. Unit GAC300N10LWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 3/8in port, a 5 um element for fine particle retention, and a nylon bowl. The lower-pressure type restricts regulation to 0.15-0.4 MPa (20-58 psi), making it suitable for sensitive actuators.
Air passes through the filter first, then the regulator, before oil mist is introduced by the lubricator, ensuring the regulator seat stays clean. The assembly includes a semi-auto and manual drain pair, plus a fitted circular gauge reading MPa/psi. Weighing 1300 g, the body holds 60 cc of condensate and 98 cc of oil. Order code GAC300N10LWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N10LWT |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to sensitive analytical instruments requiring fine 5 um filtration without high force.
Supplies a steady, lubricated air supply to delicate spinning actuators operating below 0.4 MPa.
Conditions air for light-duty clamping fixtures that rely on soft gripping forces and clean air.
Choose this GAC300 size class when a machine requires very fine 5 um filtration alongside low operating pressures. The nylon bowl offers a lightweight alternative to the standard PC or metal options, though buyers should confirm chemical compatibility for aggressive environments. If the downstream line must remain completely free of oil, omit the lubricator and select a standalone filter-regulator instead. Replacement parts follow the same 3/8in body-port suffix: GAF300-10, GAR300-10 and GAL300-10.
Stepping down to the GAC200 body drops the plotted flow envelope from 3000 L/min to 1750 L/min at 0.7 MPa inlet, halving the available air capacity. Because the lower-pressure type tops out at 0.4 MPa, it provides only 44% of the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It features a 60 cc drain bowl, a 98 cc oil bowl, and weighs 1300 g. The recommended lubricant is ISO VG 32.
The W in the model code specifies a 5 um element, which traps finer particles than the standard 40 um filter for precision valves. The L indicates a lower-pressure type, limiting the setpoint to 0.4 MPa for applications that cannot tolerate higher forces.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.