The AirTAC GAC F.R.L. Unit GAC300N10SNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. It features a 3/8in port and operates within the standard 0.15-0.9 MPa (20-130 psi) range. The 5 um element traps far finer particles than the default 40 um grade, suiting precision valves, while the nylon bowl keeps the total mass at 1300 g.
Because no gauge is supplied, operators must add one to the 1/8in gauge connection to read the set pressure. The reverse-flow (reflux) valve is fitted, which the catalogue shows as a separate pneumatic symbol with details on its own page. Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC300N10SNWTK |
|---|---|
| Series | GAC300 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Nylon |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 60 cc |
| Capacity of oil bowl | 98 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 1300 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC300 is 1/8" if you add one.
| GAC300 | GA300 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| N | Bowl material: Nylon. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF300-10 filter, GAR300-10 regulator, GAL300-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC300 · 3/8" · curve to 3000 L/min |
|---|---|
| One size down | GAC200 |
| One size up | GAC400 (curve to 6000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds instrument air to tight-tolerance directional valves where the 5 um element prevents sticking and premature wear on internal spools.
Conditions air for high-speed packaging lines, adding a controlled oil mist to protect sealing jaws and rotary actuators from rapid wear.
Supplies a steady 3/8in line for pneumatic clamps and bending dies, relying on the nylon bowl to handle routine workshop splashes.
Choose this configuration when you need the 5 um filtration for sensitive instrumentation but want the standard 0.15-0.9 MPa (20-130 psi) operating window. The semi-auto and manual drain pair is fitted, discharging condensate on each pressure drop or on demand into the 60 cc bowl. If your machine requires oil-free air downstream, you must omit the lubricator and choose a filter-regulator instead. For maintenance, the assembly accepts individual GAF300-10, GAR300-10 and GAL300-10 replacement units. The catalogue flow curve for the GAC300 is plotted to 3000 L/min at 0.7 MPa inlet, which is double the 1750 L/min envelope of the smaller GAC200. Keep in mind the 1.5x overpressure margin: the 1.5 MPa proof pressure against a 1.0 MPa maximum is a burst-test margin, not permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates from 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 1300 g, and uses a 60 cc drain bowl alongside a 98 cc oil bowl. The recommended lubricant is ISO VG 32.
This model ships without a gauge, so the set pressure cannot be read directly. You can install a circular gauge into the 1/8in gauge connection; for the default NPT thread, the matching scale reads in MPa/psi.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.