The AirTAC GAC F.R.L. Unit GAC40010ALNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in ported GAC400 body carries a 40 um element and an automatic drain that empties the 100 cc condensate bowl without operator input. Because the lubricator sits last in the sequence, oil mist is introduced downstream of the regulator seat, preventing fouling during pressure control.
Configured for low-pressure duties, the unit regulates between 0.15-0.4 MPa (20-58 psi) and ships without a gauge. Operators can add a pressure indicator later using the 1/4in gauge connection. Weighing 2390 g, the assembly needs a firm panel or frame mount rather than relying on the connected tubing for physical support. Order code GAC40010ALNT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40010ALNT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate pneumatic grippers on electronics assembly lines where actuator forces must stay within the 0.15-0.4 MPa window to avoid crushing components.
Conditions air for low-pressure packaging cylinders that pull film and form bags, relying on the automatic drain to clear condensate during long continuous shifts.
Supplies metered oil mist and stable low pressure to test benches driving small diaphragm pumps, with the 40 um element protecting sensitive metering valves.
Choose this lower-pressure variant when your actuators or instruments operate strictly within a 0.15-0.4 MPa range; if the machinery might ever require a higher setting, the L type becomes the wrong component since it tops out at 0.4 MPa. The PC bowl is standard for general environments, while the automatic drain suits unattended stations or wet air lines. Because no gauge is supplied, the set pressure cannot be read unless one is added to the 1/4in port. If the downstream line must remain completely free of oil, omit the lubricator and select a dedicated filter-regulator instead. For maintenance, the individual elements are available as GAF400-10, GAR400-10 and GAL400-10. The catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet, which is exactly double the 3000 L/min envelope of the GAC300. Furthermore, the 0.4 MPa ceiling is 44% of the standard 0.9 MPa maximum, quantifying the regulation capacity sacrificed by choosing this low-pressure type.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi). It shares the common maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). Operating temperature is -5 to 70 C, and the recommended lubricant is ISO VG 32. The drain bowl holds 100 cc, the oil bowl holds 185 cc, and the unit weighs 2390 g.
The N in the ordering code denotes that no circular gauge is supplied. To monitor the 0.15-0.4 MPa setting, a separate gauge must be fitted to the 1/4in gauge connection on the body. The default NPT thread means any added gauge should read in MPa/psi.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.