The AirTAC GAC F.R.L. Unit GAC40010ALNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatic setups, this GAC400 unit combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/8in port pairs with a 2390 g body mass, requiring a firm panel or frame mount rather than tubing support. Because the 40 um filter sits first in the sequence, moisture and grit are stripped out before the air reaches the regulator, while the oil mist is injected last so it never fouls the internal regulator seat.
Configured for low-pressure duties, the regulator operates within a 0.15-0.4 MPa (20-58 psi) range. The automatic drain actively clears condensate from the 100 cc bowl without an operator, which is ideal for unattended or wet lines. No pressure gauge is supplied, but a 1/4in connection is ready if you need to add one. A reverse-flow (reflux) valve is fitted, shown as a separate pneumatic symbol in the catalogue on its own page. Order code GAC40010ALNTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40010ALNTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds delicate bagging and sealing actuators where operating pressure must stay below 0.4 MPa to prevent crushing thin films.
Conditions air for multi-station pick-and-place units, using the 100 cc automatic drain to handle condensate during long unattended shifts.
Supplies stable, lubricated air to benchtop dispensing robots and clamps without over-pressurizing sensitive glass or plastic fixtures.
Choose this assembly when your machine needs a maximum of 0.4 MPa, as the lower-pressure type tops out well below the 0.9 MPa standard range. If the application must stay completely oil-free, you should select a filter-regulator instead, because the lubricator here intentionally adds oil mist downstream. The PC bowl carries the same 1.0 MPa maximum and -5 to 70 C temperature limits as the metal and nylon options, so confirm material compatibility for aggressive surroundings. Should a component fail, order the individual GAF400-10, GAR400-10 or GAL400-10 spares rather than replacing the whole set. Stepping up to this body gives a 6000 L/min plotted flow envelope at 0.7 MPa inlet, which is double the GAC300 capacity, but remember the 0.4 MPa ceiling is 44% of the standard type limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 2390 g, and pairs a 100 cc drain bowl with a 185 cc oil bowl using ISO VG 32 lubricant.
The N in the code means no gauge is supplied, leaving a 1/4in gauge port open for you to install one. You cannot read the set pressure without adding that gauge, and the default NPT thread dictates an MPa/psi scale if you order the AirTAC accessory.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.