The AirTAC GAC F.R.L. Unit GAC40010ALNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, this AirTAC GAC40010ALNWT F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port serves mid-scale duties, while the 5 um element captures fine particulates for sensitive valves. Because oil mist is introduced downstream of the regulator seat, the internal mechanism avoids fouling. An automatic drain clears condensate from the 100 cc bowl without operator intervention.
This lower-pressure type operates at 0.15-0.4 MPa (20-58 psi), making it suitable for low-force actuator circuits. No gauge is supplied, but the body features a 1/4in gauge connection if monitoring is added later. The 185 cc oil reservoir sets the lubrication service interval. At 2390 g, the assembly requires a solid panel or frame mount rather than tubing support. The catalogue flow curve for the GAC400 is plotted to 6000 L/min at 0.7 MPa inlet for sizing. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40010ALNWT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure instrument air to sensitive solenoid valve manifolds, leveraging the 5 um element to prevent particulate sticking.
Conditions air for low-force pneumatic stoppers and diverter cylinders on packaging lines operating safely below 0.4 MPa.
Regulates delicate air pressure for test fixtures and small actuator rigs where the automatic drain prevents moisture ingress during unattended overnight runs.
Choose this assembly for low-pressure circuits requiring fine filtration and unattended condensate management. The PC bowl handles standard plant environments, while the automatic drain suits wet lines. If a machine might ever exceed 0.4 MPa, the L type is the wrong part, as it caps at 0.15-0.4 MPa (20-58 psi). Because no gauge is included, the set pressure cannot be read without adding one to the 1/4in connection. For oil-free downstream requirements, omit the lubricator and choose a filter-regulator instead. Spares follow the body-port suffix: GAF400-10, GAR400-10 and GAL400-10. Stepping up to the GAC500 roughly doubles the plotted flow envelope to 7000 L/min at 0.7 MPa inlet. The lower-pressure ceiling of 0.4 MPa is about 44% of the Standard type's 0.9 MPa maximum.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 2390 g, and pairs a 100 cc condensate bowl with a 185 cc oil bowl. The recommended lubricant is ISO VG 32.
The N in the code indicates no gauge is supplied. The body retains a 1/4in gauge connection, allowing operators to install a separate NPT-threaded gauge reading MPa/psi to monitor the 0.15-0.4 MPa range.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.