The AirTAC GAC F.R.L. Unit GAC40010ALWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, lubricated and precisely metered air, this assembly integrates a filter, regulator and lubricator onto a single L-shape bracket with quick mounting clamps. The 3/8in port serves mid-volume duties, while the 5 um element captures fine particulates ahead of sensitive pneumatics. Because the lubricator sits downstream of the regulator, oil mist never fouls the pressure-control seat.
This variant operates within the lower 0.15-0.4 MPa (20-58 psi) pressure band, making it unsuitable for any system that might later require higher actuator force. An automatic drain clears condensate from the 100 cc bowl without operator intervention. The assembly includes a reverse-flow (reflux) valve, which the catalogue depicts as a separate pneumatic symbol on its own page, and a fitted circular gauge reading MPa/psi for the default NPT thread. Order code GAC40010ALWTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40010ALWTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds instrument-quality air to sensitive solenoid banks requiring 5 um filtration and very low, stable actuation pressures.
Protects delicate film-handling cylinders by regulating down to 0.4 MPa, preventing tearing while supplying steady oil mist.
Conditions air for benchtop test rigs where the automatic drain handles condensate removal without interrupting ongoing experiments.
Choose this configuration for machines needing very low, stable downstream pressures and fine 5 um filtration. If the equipment could ever exceed 0.4 MPa, the L type is the wrong choice; a standard S type would be required instead. The 100 cc condensate bowl and 185 cc oil reservoir dictate the maintenance rhythm, demanding fewer interventions than a smaller GAC300 with its 60 cc drain capacity. The automatic drain is decisive for unattended or wet lines, and the fitted NPT-thread gauge lets operators verify the setpoint directly. Note that oil mist is added to the downstream air, so select a filter-regulator instead if the line must remain strictly oil-free. Should a component fail, the assembly breaks down into separately orderable spares: GAF400-10, GAR400-10 and GAL400-10. Stepping up to a GAC500 roughly doubles the flow envelope from 6000 to 7000 L/min at 0.7 MPa inlet, but choosing the lower-pressure L type caps your usable output at 44% of the standard 0.9 MPa ceiling.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi) against a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -5 to 70 C, weighs 2390 g, and features a 100 cc drain bowl alongside a 185 cc oil bowl. The recommended lubricant is ISO VG 32.
The A signifies an automatic drain that expels condensate without manual effort, while L restricts the pressure range to 0.15-0.4 MPa. W specifies a 5 um fine filter element, and K indicates a reverse-flow (reflux) valve is fitted, shown as a distinct pneumatic symbol in the catalogue.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.