The AirTAC GAC F.R.L. Unit GAC40010ASNTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air, this AirTAC GAC40010ASNTK combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. It features a 3/8in port, a 40 um element and a standard pressure range of 0.15-0.9 MPa (20-130 psi). The automatic drain clears condensate without an operator, which is decisive for unattended or wet lines.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the oil never fouls the regulator seat. This model includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with details on its own page. No gauge is supplied, but a 1/4in gauge connection is available if you need to read the set pressure later. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40010ASNTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds multiple pneumatic wrenches and actuators on a car production line, relying on the 100 cc drain bowl to handle condensate from heavy daily air usage.
Provides steady 0.15-0.9 MPa air to continuous motion box tapers, with the automatic drain preventing water spit-through during long shifts.
Conditions air for high-speed pneumatic pushers on logistics conveyors, where the 40 um element protects sliding seals from particulate wear.
Choose this 2390 g GAC400 unit when a smaller body lacks capacity; its flow envelope is plotted to 6000 L/min at 0.7 MPa inlet, exactly double the 3000 L/min envelope of the GAC300. The PC bowl, 100 cc drain capacity and 185 cc oil bowl suit general factory air. If the downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. The three units are separately orderable as GAF400-10, GAR400-10 and GAL400-10, so a clogged element does not mean replacing the whole assembly. Because the max supply is 1.0 MPa and the Standard type regulates to 0.9 MPa, there is only about 0.1 MPa of headroom above the top setting.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It has a 3/8in port, a 100 cc drain bowl, a 185 cc oil bowl, a 40 um element, and weighs 2390 g. The temperature range is -5 to 70 C and the recommended lubricant is ISO VG 32.
The N in the ordering code means no gauge is supplied. The body features a 1/4in gauge connection, allowing you to install a separate gauge if you need to monitor the 0.15-0.9 MPa outlet pressure.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.