The AirTAC GAC F.R.L. Unit GAC40010ASWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatic setups, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in ported body operates at 0.15-0.9 MPa (20-130 psi) and uses a 5 um element to trap fine particulates before they reach precision valves. A fitted circular gauge reads in MPa/psi for the default NPT thread, while the automatic drain clears condensate without an operator.
Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Weighing 2390 g, this assembly requires a solid panel or frame mount rather than tubing support. The 100 cc condensate bowl and 185 cc oil reservoir dictate the maintenance rhythm, and this specific configuration includes a reverse-flow (reflux) valve, which the catalogue shows as a separate pneumatic symbol with details on its own page. Order code GAC40010ASWTK has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40010ASWTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds tool changers and high-speed spindles where the 5 um element protects sensitive pneumatic tooling from fine particulate ingress.
Conditions air for continuous packaging machinery, utilizing the automatic drain to handle condensate during extended unattended production runs.
Supplies regulated, lubricated air to multi-actuator robotic welding cells, relying on the 100 cc drain bowl to manage moisture in high-cycle operations.
Choose this 3/8in model for medium-duty lines needing fine 5 um filtration, stepping up from the GAC300 which offers a 3000 L/min plotted flow envelope at 0.7 MPa inlet compared to the 6000 L/min curve of this GAC400 body. The PC bowl handles standard 1.0 MPa (145 psi) max pressures, and the automatic drain suits unattended or wet installations. Because oil mist is added downstream, select a separate filter-regulator instead if the downstream line must remain strictly oil-free. Should a component fail, order the individual GAF400-10, GAR400-10 or GAL400-10 spares rather than replacing the whole assembly. Stepping from the GAC300 to this GAC400 body doubles the flow envelope, providing a 2x capacity increase for sizing your air system.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit regulates 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It operates from -5 to 70 C, weighs 2390 g, features a 100 cc drain bowl and a 185 cc oil bowl, and uses ISO VG 32 lubricant.
The K indicates a reverse-flow (reflux) valve is fitted. The catalogue illustrates this as a distinct pneumatic symbol on its own page, representing an ordering difference for this specific assembly.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.