The AirTAC GAC F.R.L. Unit GAC40010LNWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, lubricated air at a strictly controlled lower pressure, this AirTAC F.R.L. combination integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port serves mid-scale pneumatics, while the 5 um element captures fine particulates for sensitive valves. Because the set pressure cannot be read without adding a gauge, the body leaves the factory with a 1/4in gauge connection ready for one to be fitted later.
Air passes through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. The PC bowl pairs with a semi-auto and manual drain, holding 100 cc of condensate and 185 cc of oil. Operating strictly between 0.15-0.4 MPa (20-58 psi), it suits machinery requiring gentle actuation rather than full-line force. Order code GAC40010LNWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40010LNWT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure air to sensitive analytical instruments and glassware handling actuators where a 5 um element prevents particulate contamination.
Regulates gentle clamping forces on flow-wrapping machines, ensuring delicate film webs are not torn by excessive cylinder thrust.
Supplies a steady, oil-misted air supply to low-friction yarn guides and small-bore cylinders operating well below standard line pressure.
Choose this 2390 g assembly for mid-capacity lines needing precision filtration and low-pressure regulation. The 5 um element protects delicate instrumentation but demands more frequent replacement than the standard 40 um mesh. A semi-auto drain dumps condensate on every pressure drop, supplemented by a manual override, while the PC bowl suits standard ambient environments. If the downstream line must remain completely oil-free, omit the lubricator and select a dedicated filter-regulator instead. Should a component fail, order the individual GAF400-10, GAR400-10 or GAL400-10 spares rather than replacing the whole bracket.
The 0.4 MPa upper limit is exactly 44% of the standard 0.9 MPa ceiling, so verify your actuators never require more force than this lower range permits.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This lower-pressure unit regulates from 0.15-0.4 MPa (20-58 psi), with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates between -5 to 70 C, weighs 2390 g, and features a 100 cc drain bowl alongside a 185 cc oil reservoir. The recommended lubricant is ISO VG 32.
The N in the ordering code signifies no gauge is supplied. The block retains a 1/4in gauge connection, allowing operators to install a compatible MPa/psi scale gauge matching the default NPT thread, ensuring the 0.15-0.4 MPa setpoint can be visually verified.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.