The AirTAC GAC F.R.L. Unit GAC40010LWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
Delivering cleaned, regulated and lubricated air for downstream pneumatics, the AirTAC GAC40010LWT is a three-unit F.R.L. combination pre-plumbed on a single L-shape bracket. This specific assembly features a 3/8in port, a PC bowl, and a 5 um element for trapping finer particles. Because it is a lower-pressure type, the regulator operates within a 0.15-0.4 MPa (20-58 psi) range.
The internal flow path passes through the filter first, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. A circular gauge reading MPa/psi is fitted to match the default NPT threads, allowing operators to monitor the set pressure directly. The unit carries a 2390 g mass and uses a 100 cc condensate bowl paired with a 185 cc oil reservoir.
| Model | Airtac GAC F.R.L. Unit GAC40010LWT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds low-pressure actuated valves and sensitive analytical instruments requiring highly filtered, lubricated air at stable sub-0.4 MPa pressures.
Conditions air for delicate spinning and weaving cylinders where standard 0.9 MPa pressure would damage fragile fibers or delicate tensioning components.
Supplies regulated, finely filtered air to low-force capping heads, ensuring consistent torque on bottles without over-pressurizing the pneumatic grippers.
Choose this 400-series body when a 3/8in line requires precision filtration and low-pressure regulation. The 5 um element catches far finer particulates than the standard 40 um grade, making it suitable for sensitive instrument air, though it will require more frequent element changes. The semi-auto and manual drain pair fitted here dumps condensate on every pressure drop or on demand, while the PC bowl suits standard -5 to 70 C environments. If the downstream line must remain completely oil-free, omit the lubricator and choose a separate filter-regulator instead. For maintenance, the individual elements are separately orderable as GAF400-10, GAR400-10 and GAL400-10. Stepping up to this unit from a GAC300 increases the plotted flow envelope from 3000 to 6000 L/min at 0.7 MPa inlet, doubling the sizing capacity. Remember that the 0.4 MPa upper limit is 44% of the standard type's 0.9 MPa ceiling, so select this L-type only if the machinery will never require higher operating pressure.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
The lower-pressure type operates at 0.15-0.4 MPa (20-58 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It functions in temperatures from -5 to 70 C, uses a 100 cc drain bowl, a 185 cc oil bowl, weighs 2390 g, and requires ISO VG 32 lubricant.
The W code specifies a 5 um filtering grade rather than the default 40 um. This traps much finer solid particles, protecting precision valves and instrument air systems, but the tighter mesh means the element will clog faster and require more frequent replacement.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.