The AirTAC GAC F.R.L. Unit GAC40010SNWTK is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for mid-size pneumatic setups, this AirTAC GAC40010SNWTK combines a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port feeds a standard pressure range of 0.15-0.9 MPa (20-130 psi), while the 5 um element traps fine particles for sensitive downstream valves. Because the lubricator sits last in the sequence, oil mist is added downstream of the regulator seat, preventing fouling during pressure modulation.
Weighing 2390 g, this body requires a solid panel or frame mount rather than tubing support. It carries a 100 cc condensate bowl and a 185 cc oil reservoir, extending the interval between maintenance visits compared to smaller bodies. No gauge is supplied, but a 1/4in gauge connection allows operators to add instrumentation for reading the set pressure. The reverse-flow valve is fitted, appearing as a distinct pneumatic symbol in the catalogue. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC40010SNWTK |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Supplies finely filtered, lubricated air at 5 um to precision pneumatic tool changers and spindle clamps on mid-sized CNC machining centers.
Conditions air for the high-speed pneumatic cutting and sealing cylinders on continuous motion flow wrapping lines.
Feeds pilot and directional valves on automated stamping presses where consistent 0.15-0.9 MPa pressure and oil mist protect moving spools.
Choose this 3/8in unit for duties needing fine 5 um filtration without an integrated pressure readout, relying on the 1/4in gauge port for custom instrumentation. The PC bowl suits general industrial environments, and the semi-auto and manual drain pair handles condensate on demand. If a machine requires absolutely oil-free output, omit the lubricator and select a standalone filter-regulator instead. The three internal units are separately orderable as GAF400-10, GAR400-10 and GAL400-10, so a clogged element never forces replacing the whole assembly. Stepping down to the GAC300 halves the plotted flow envelope to 3000 L/min at 0.7 MPa inlet, whereas this 400 body traces 6000 L/min, giving it a 2x capacity advantage over its smaller neighbor.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This model operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It functions in temperatures from -5 to 70 C, uses a 5 um element, and weighs 2390 g. The condensate bowl holds 100 cc and the oil bowl holds 185 cc, requiring ISO VG 32 or equivalent lubricant.
The N in the code means no gauge is supplied, though a 1/4in connection is provided if you need to add one later to read the set pressure. The K indicates a reverse-flow valve is fitted, which the catalogue details as a separate pneumatic symbol on its own page.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.