The AirTAC GAC F.R.L. Unit GAC400C10ASNT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic machinery, this AirTAC GAC400C10ASNT combines a filter, regulator and lubricator on a single L-shape bracket with quick mounting clamps. The 3/8in port pairs with a standard pressure range of 0.15-0.9 MPa (20-130 psi) and a 40 um element. Because the air passes through the filter first, then the regulator, and the lubricator last, the oil mist is introduced downstream of the regulator seat to prevent fouling.
This specific configuration uses a robust metal bowl and an automatic drain that clears condensate without an operator, making it well suited to unattended or wet lines. No gauge is supplied, but the body features a 1/4in gauge connection if you need to add one later to read the set pressure. The assembly carries a mass of 2390 g, requiring a proper panel or frame mount rather than relying on the tubing for support. This version has NPT ports (the T in the order code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC400C10ASNT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAC400 is 1/4" if you add one.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/4" gauge connection. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds main air headers for multi-station assembly machinery where a 3/8in port and 6000 L/min flow envelope handle high cyclic demand.
Supplies oil-misted air to the moving grippers and sealing jaws in continuous packaging equipment via its automatic drain.
Conditions air for pneumatic tool release mechanisms on machining centers, relying on the 40 um element to protect precision valves.
Choose this metal bowl variant for harsher environments where a standard PC bowl might not hold up, keeping in mind the 1.0 MPa maximum pressure and -5 to 70 C temperature limits apply equally across all bowl materials. The automatic drain is decisive for wet lines, whereas the blank drain option ships both semi-auto and manual versions. Since this is an N code, no gauge is fitted; you will need to add one to the 1/4in connection to read the outlet pressure. If your downstream line must stay oil-free, omit the lubricator and choose a filter-regulator instead. For maintenance, the three units are separately orderable as GAF400-10, GAR400-10 and GAL400-10. Stepping down to the GAC300 halves the plotted flow envelope from 6000 L/min to 3000 L/min at 0.7 MPa inlet, whereas the 100 cc drain bowl here holds about 1.7x the condensate of the GAC300's 60 cc bowl, meaning fewer interventions. The 1.5 MPa proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, but this is not permission to run above 1.0 MPa.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type F.R.L. combination operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, the filtering grade is 40 um, and it uses an ISO VG 32 lubricant. The drain bowl holds 100 cc and the oil bowl holds 185 cc, with a total weight of 2390 g.
The N after the port in the model code indicates no gauge is supplied. The unit has a 1/4in gauge connection on the regulator, so you can install a separate gauge reading MPa/psi for the default NPT thread to monitor your set pressure.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.