The AirTAC GAC F.R.L. Unit GAC400C10AST is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for pneumatic systems, this GAC400C10AST assembly integrates a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port pairs with a 40 um element and a standard pressure range of 0.15-0.9 MPa (20-130 psi). A circular gauge is fitted, reading MPa/psi for the default NPT thread, so operators can verify the setpoint at a glance.
The metal bowl equips this unit for rugged industrial surroundings, while the automatic drain empties the 100 cc condensate sump without manual intervention. Air passes through the filter, then the regulator, and finally the lubricator, ensuring oil mist is added downstream so the regulator seat never fouls. Weighing 2390 g, the assembly requires a firm panel or frame mount rather than tubing support.
| Model | Airtac GAC F.R.L. Unit GAC400C10AST |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds main air headers for robotic welding cells where a steady 0.8 MPa supply and automatic condensate removal keep heavy cylinders stroking without interruption.
Conditions air for continuous motion folders and sealers, using the 185 cc oil bowl to supply sufficient lubricant for high-speed pneumatic grippers over long shifts.
Protects diverter actuators on parcel sorting conveyors by trapping 40 um particulates and regulating pressure to prevent rapid stroke wear.
Choose this 3/8in body when a smaller GAC300 with its 60 cc drain bowl would demand too frequent intervention, as the 100 cc sump here holds significantly more condensate. The automatic drain suits unattended or wet lines, whereas a blank drain code ships both semi-auto and manual options. If the downstream line must remain strictly oil-free, omit the lubricator and select a separate filter-regulator instead. Should the element clog, order the GAF400-10, GAR400-10 and GAL400-10 spares individually. Stepping up to the GAC500 roughly doubles the flow envelope to 7000 L/min at 0.7 MPa inlet, but the proof pressure of 1.5 MPa against the 1.0 MPa maximum provides a 1.5x burst-test margin here.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type unit operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It functions from -5 to 70 C, uses a 100 cc drain bowl and a 185 cc oil bowl, weighs 2390 g, and requires ISO VG 32 lubricant.
The automatic drain discharges condensate from the 100 cc sump whenever it accumulates, eliminating the need for an operator to manually cycle a valve. The metal bowl provides a robust housing for the filter and lubricator, suitable for harsher industrial environments where polycarbonate might risk impact damage.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.