The AirTAC GAC F.R.L. Unit GAC400C10ASWT is a genuine three-unit F.R.L. combination — a filter, a pressure regulator and a lubricator pre-assembled on one bracket with quick mounting clamps. It has 3/8" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
Delivering cleaned, regulated and lubricated air for demanding pneumatic systems, this AirTAC unit combines a filter, regulator and lubricator on a single L-shape bracket. The 3/8in port pairs with a 5 um element to trap fine particulates before they reach precision valves. A metal bowl houses the assembly, which operates within a 0.15-0.9 MPa (20-130 psi) standard pressure range.
The automatic drain clears condensate from the 100 cc bowl without operator intervention, while a circular gauge reads MPa/psi for the default NPT thread. Weighing 2390 g, the assembly introduces oil mist downstream of the regulator to protect moving parts without fouling the pressure seat. If a process requires completely dry air, select a separate filter-regulator instead, as this unit actively adds oil. Order code GAC400C10ASWT has NPT ports (the T in the code) for North American pipe fittings.
| Model | Airtac GAC F.R.L. Unit GAC400C10ASWT |
|---|---|
| Series | GAC400 F.R.L. combination |
| Port size | 3/8" (NPT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 100 cc |
| Capacity of oil bowl | 185 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 2390 g |
Specifications follow the official AirTAC GAC catalogue (pages 216-217). Air must not freeze in the unit. The fitted circular gauge reads in psi / bar, set by the NPT thread code.
| GAC400 | GA400 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 10 | Port size 3/8". This body offers 10 = 3/8", 15 = 1/2". |
| A | Drain: Automatic drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| T | NPT thread; gauge scale psi / bar. |
| (blank) | No reverse-flow valve. |
Constituent units, orderable separately as spares: GAF400-10 filter, GAR400-10 regulator, GAL400-10 lubricator — all three share this body and port.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAC400 · 3/8" · curve to 6000 L/min |
|---|---|
| One size down | GAC300 |
| One size up | GAC500 (curve to 7000 L/min) |
| Build order | Filter → bracket → regulator → lubricator |
Feeds clean, lubricated air at a stable pressure to pneumatic tool-release cylinders on machining centers, preventing stiction during rapid tool swaps.
Conditions air for high-speed flow wrappers and sealing jaws, where the 5 um element stops dust from clogging tiny nozzle orifices.
Supplies multiple pick-and-place actuators in a robotic cell, utilizing the automatic drain to handle condensate during continuous three-shift operation.
Choose this 5 um metal-bowl configuration for unattended lines where manual draining is impractical and fine filtration protects sensitive instrumentation. Stepping down to the GAC300 reduces the flow envelope to 3000 L/min at 0.7 MPa inlet, whereas this GAC400 is plotted to 6000 L/min, doubling the available capacity. The 5 um element requires more frequent replacement than the 40 um standard, but the separately orderable GAF400-10, GAR400-10 and GAL400-10 spares prevent full assembly replacement. Remember that the 1.5 MPa (215 psi) proof pressure provides a 1.5x burst-test margin over the 1.0 MPa maximum, which is not permission to run above the 1.0 MPa limit.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a filter-regulator instead of an F.R.L. combination on that branch.
This standard type operates at 0.15-0.9 MPa (20-130 psi) with a maximum pressure of 1.0 MPa (145 psi) and a 1.5 MPa (215 psi) proof pressure. It features a 3/8in port, a 5 um element, a 100 cc drain bowl and a 185 cc oil bowl. The unit weighs 2390 g, runs from -5 to 70 C, and uses ISO VG 32 lubricant.
The metal bowl offers durability in harsh industrial settings, and the 5 um element captures far finer particles than the 40 um standard, making it suitable for precision valves or instrument air. The automatic drain attached to the metal bowl expels condensate continuously without manual intervention.
T selects NPT port threads, the North American taper pipe standard. Without it the same order code has PT (Rc) ports, and with G it has G (BSPP) ports; body, function and dimensions do not change.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Most standard models are dispatched in 3-5 days.
Most inquiries answered within 7 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.